| Application Description: |
Imperial Overhead Crane Warehouse Building One 529m2 Part 9, F-2 use building with 108.6m2 office use mezzanine under BCBC1998. Building is sprinklered by bylaw and equivalency, has a non-combustible shell with combustible mezzanine and a fire alarm system. No fire resistance rating required for the mezzanine and roof. Water curtain equivalency by GHL for spatial separation construction requirements. Two washrooms supplied, one to meet "accessibility" requirements. Future permit required for second building. Sept. 13, 07 Mezz. changed to second floor, 3/4 hr FS/FRR required at floor, wall of second floor and exit passageway on main floor. 3/4 hr FRR for supports of 2nd floor required, single exit ok for 2nd floor with office use only. Two more plumbing fixtures added. See note to file VS |
| Application Status: | HOLDBACK |
| Permit Value: | $232,600.00 |
| Issued Date: | February 13, 2007 |
| File Close Date: | November 30, 2007 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 881 MAUGHAN ROAD | I4 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
FIRELINE
Fireline for the sprinkler system must be complete and visable for inspection. |
PARTIAL |
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
FAILED |
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PASSED |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
FAILED |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PASSED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
FAILED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
| OCCUPANCY-OLD | FAILED |
| OCCUPANCY-OLD |
PASSED
2007-11-30 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)