BP110946 - 4515 Uplands
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP110946 - 4515 Uplands | |
|---|---|
| Neighbourhood: | Rutherford |
| Street Address: | 4515 Uplands |
| Type of Application: | Commercial / Multi / Industrial |
| File Number: | BP110946 |
| Date Application Submitted: | November 30, 2006 |
| Application Description: |
Songbird Office Bld - 387.4 sq m, 2 storey office building, combustible construction, sprinklered with fire alarm system. Travel distance & single exit from basement and upper floor based on sprinklered building with fire alarm system under Part 3 1998 BCBC. 387.4 m2 main floor office, 279.7m2 second floor office, 134.5m2 basement storage area. 3/4 hr fire separation between floors and between "exit" stairwell and suites. Roof to have 3/4 hr rating to separate stairwell from adjoining suites. No fire separation required between office suites. Future permits required to complete and occupy tenant spaces. Feb. 20, 07 revised storage basement to 387.4m2, use to be subsidiary to office use only. Bld changed to A-2, see BP111580 - Plans received & approved July 24,07. VS |
| Application Status: | COMPLETED |
| Permit Value: | $630,000.00 |
| Builder: | DUECK GENERAL CONTRACTING |
| Issued Date: | February 09, 2007 |
| File Close Date: | October 09, 2007 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 4515 UPLANDS DRIVE | COR2 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
CANCELLED |
|
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
CANCELLED |
|
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PASSED |
|
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PASSED |
|
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PASSED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
CANCELLED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
|
PAPER/FLASHING/WATERPROOFING
When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco. |
PASSED |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
CANCELLED |
|
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
CANCELLED |
|
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
CANCELLED |
|
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
|
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PASSED |
|
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
FAILED |
| OCCUPANCY-OLD | FAILED |
|
FINAL-OLD
Final approval as per requirements on plans. |
PASSED
2007-10-09 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)