BP110946 - 4515 Uplands

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP110946 - 4515 Uplands
Neighbourhood: Rutherford    
Street Address: 4515 Uplands
Type of Application: Commercial / Multi / Industrial
File Number: BP110946
Date Application Submitted: November 30, 2006
Application Description: Songbird Office Bld - 387.4 sq m, 2 storey office building, combustible construction, sprinklered with fire alarm system. Travel distance & single exit from basement and upper floor based on sprinklered building with fire alarm system under Part 3 1998 BCBC. 387.4 m2 main floor office, 279.7m2 second floor office, 134.5m2 basement storage area. 3/4 hr fire separation between floors and between "exit" stairwell and suites. Roof to have 3/4 hr rating to separate stairwell from adjoining suites. No fire separation required between office suites. Future permits required to complete and occupy tenant spaces.

Feb. 20, 07 revised storage basement to 387.4m2, use to be subsidiary to office use only. Bld changed to A-2, see BP111580 - Plans received & approved July 24,07. VS
Application Status: COMPLETED
Permit Value: $630,000.00
Builder: DUECK GENERAL CONTRACTING
Issued Date: February 09, 2007
File Close Date: October 09, 2007

Associated Properties

Address Zone More
4515 UPLANDS DRIVE COR2 Property Report

Process Steps

Task Status
FOOTING/FORMS

Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

CANCELLED
FOOTING/FORMS

Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

CANCELLED
FOOTING/FORMS

Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PASSED
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PASSED
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

CANCELLED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
PAPER/FLASHING/WATERPROOFING

When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco.

PASSED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

CANCELLED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

CANCELLED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

CANCELLED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PASSED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

FAILED
OCCUPANCY-OLD FAILED
FINAL-OLD

Final approval as per requirements on plans.

PASSED

2007-10-09

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.