BP110873 - 9 - 2535 McCullough - SCANNED
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP110873 - 9 - 2535 McCullough - SCANNED | |
|---|---|
| Neighbourhood: | Northfield |
| Street Address: | 9 - 2535 McCullough - SCANNED |
| Type of Application: | Leasehold Improvements |
| File Number: | BP110873 |
| Date Application Submitted: | November 08, 2006 |
| Application Description: |
Lanson Drywall - 127.2m2 F-2 suite. Work includes 7 new sprinkler heads, "accessible" washroom, 50.5m2 new mezzanine with stairs onto main floor, interior office walls. Two exits required from suite for mezzanine travel distance to work. 3/4 hr demising walls between suites existing. Existing Building 684.9m2 Bldg B warehouse, Classification BCBC1998 - 3.2.2.72. F2 up to 2 storeys, sprinklered with fire alarm system, combustible or non-combustible construction, for combustible floor assemblies 3/4 hr fire separation & supports required. No rating required for mezzanines or roof. |
| Application Status: | COMPLETED |
| Permit Value: | $16,000.00 |
| Issued Date: | December 18, 2006 |
| File Close Date: | April 20, 2007 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 9 2535 MCCULLOUGH ROAD | I3 | Property Report |
| 2535 MCCULLOUGH ROAD | I3 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible. |
PASSED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
CANCELLED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
PASSED |
|
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PASSED |
|
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PASSED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PARTIAL |
|
FINAL-OLD
Final Approval as per requirements on plans. |
PARTIAL |
|
FINAL-OLD
Final Approval as per requirements on plans. |
PASSED
2007-04-20 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)