BP110741 - 6201 Oliver
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP110741 - 6201 Oliver | |
|---|---|
| Neighbourhood: | Rutherford |
| Street Address: | 6201 Oliver |
| Type of Application: | Commercial / Multi / Industrial |
| File Number: | BP110741 |
| Date Application Submitted: | September 27, 2006 |
| Application Description: |
Senior's housing .(This permit is for Phase 2) Xreference BP110490 foundation and BP 110228 Phase 1 Residential Seniors Facility - Phase 2 - 66 units 4 storey (Based on entire building which includes phase 1 and phase 2 (this permit), Non-Combustible Senior Residential Building 3.2.2.43 with underground parking in basement and amenities. Group C, Residential and basement parkade Group F3 , sprinklered to NFPA 13, Fire alarm system , Floor assemblies 1 Hour FRR/FS, Public corridor 1hr. FRR/FS. Suite separation 1hr. FRR/FS 50 STM, Non-combustible construction required, parking storage garage 1.5 hr. FRR/FS. Exit parking garage 1.5hr. FRR/FS, Vestibules required from parkade. Duct shafts 1 hour FRR/FS, Exits 1 hour FRR/FS, Residential Suites doors 20 min labelled FPR. Other doors 1st, 2nd, 3rd storey 45min FPR. 68 parking spaces required. changed May 24, 2007. Building envelope professional design review & commitment for enhanced field review by S.K.C. LI, P.Eng. (B1,B2) |
| Application Status: | COMPLETED |
| Permit Value: | $5,342,500.00 |
| Builder: | KNAPPETT PROJECTS INC |
| Issued Date: | December 21, 2006 |
| File Close Date: | November 25, 2009 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 6201 OLIVER ROAD | COR1 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PARTIAL |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PASSED |
|
MONITORING FIELD REVIEW
A building official may attend the site from time to time during the course of construction to ascertain that the field reviews are taking place and to monitor the field reviews undertaken by the registered professional. |
PARTIAL |
|
MONITORING FIELD REVIEW
A building official may attend the site from time to time during the course of construction to ascertain that the field reviews are taking place and to monitor the field reviews undertaken by the registered professional. |
PARTIAL |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PASSED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
| OCCUPANCY-OLD | FAILED |
| OCCUPANCY-OLD |
PASSED
2009-11-25 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)