BP110358 - 2345 Delinea Place
Neighbourhood: Diver Lake    
Street Address: 2345 Delinea Place
Type of Application: Commercial / Multi / Industrial
File Number: BP110358
Date Application Submitted: May 19, 2006
Application Description: 03- 27-2007 - TI-Unit A, TI-Unit B- added 30m2 & exterior exit stair ,now is considered 2nd storey 45minFRR/FS. Group D, TI Unit C

Shenton Industrial 417.7 m2, Part 9, mixed building uses Group D/F2 / F3 occupancies. Sprinklered (bylaw), fire alarm,1 storey plus mezzanine, no rating required for mezz.. Washrooms for persons with disabilites. Accessible main floor. Suite separation 45min FRR/FS. 2 exits provided each suite. X-reference BP110359 for foundation permit.
Unit A: 1st floor=1493 sq. ft. , Mezz. 585 sq. ft. (39%), enclosed portion of mezz.97sq. ft.(%.). Total gross floor area = 2078.5sq.ft. Mezz.TD to top of stair =12m (Group D or Group F3 uses on mezz. only)
Unit B: 1st floor=1524 sq. ft., Mezz. 588sq. ft. (39.%).. Total gross floor area = 2112sq.ft.
Unit C:1st floor=1475sq. ft., Mezz.500sq. ft. (40%), enclosed portion of mezz.26.6 sq. ft.(8.2)%. Total gross floor area = 1975sq.ft.
1 hr FRR on south east (rear),south west(right),and east(left) exterior walls.
Application Status: COMPLETED
Permit Value: $464,000.00
Builder: SUPERB CONSTRUCTION LTD
Issued Date: August 23, 2006
File Close Date: July 25, 2007

Associated Properties

Address Zone More
2345 DELINEA PLACE I3 Property Report

Process Steps

Task Status
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PARTIAL
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PASSED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PASSED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

CANCELLED
PLUMBING FINAL-OLD

All fixtures must be in place.

CANCELLED
OCCUPANCY-OLD FAILED
OCCUPANCY-OLD FAILED
OCCUPANCY-OLD PARTIAL
OCCUPANCY-OLD PASSED

2007-07-25

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.