BP110168 - 83 Victoria Cres -- Drawings Scanned/Attached

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP110168 - 83 Victoria Cres -- Drawings Scanned/Attached
Neighbourhood: Downtown/Old City    
Street Address: 83 Victoria Cres -- Drawings Scanned/Attached
Type of Application: Leasehold Improvements
File Number: BP110168
Date Application Submitted: May 03, 2006
Application Description: Nanaimo Association for Community Living (NACL); Renovation to existing Group D building. Works consists of new Sprinklers throughout and new Fire alarm system and Structural Seismic upgrade.
Existing floor areas = basement 288.2m2 ( two suites for office use only basement, existing) ,1st storey = 562.2 m2 (Group D ), second storey = 607m2 (two suites for office use only) . Building Classification = 3.2.2.56, Group D, 2 stories with basement, No FRR/FS for Group D occupancy suite separation/ public corridor, 45 floor assemblies if combustible however existing non-combustible construction no rating required only fire separations. Existing exit with 45min FRR/FS. Electromagnetic lock hardware on 1st storey to be in compliance with 3.4.6.15. Accessible for persons with disabilites 1st storey.

Existing Part 3 Building, Group D Building,
Application Status: COMPLETED
Permit Value: $550,000.00
Building Area: 1,457.40 M2
15,687.31 ft2
Builder: HAZELWOOD CONSTRUCTION SERVICES INC
Issued Date: June 19, 2006
File Close Date: January 05, 2007

Associated Properties

Address Zone More
83 VICTORIA CRESCENT DT4 Property Report

Process Steps

Task Status
UNDERSLAB PLUMBING

Complete underslab plumbing must be visible.

PARTIAL
UNDERSLAB PLUMBING

Complete underslab plumbing must be visible.

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

FAILED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visible for inspection.

PARTIAL
FRAMING

Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval.

PASSED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PARTIAL
FINAL-OLD

Final Approval as per requirements on plans.

FAILED
FINAL-OLD

Final Approval as per requirements on plans.

CANCELLED
FINAL-OLD

Final Approval as per requirements on plans.

CANCELLED
FINAL-OLD

Final Approval as per requirements on plans.

PASSED

2007-01-05

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.