BP110136 - 2035 Boxwood
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP110136 - 2035 Boxwood | |
|---|---|
| Neighbourhood: | Northfield |
| Street Address: | 2035 Boxwood |
| Type of Application: | Commercial / Multi / Industrial |
| File Number: | BP110136 |
| Date Application Submitted: | April 26, 2006 |
| Application Description: |
1324m2 Pre-engineered steel shell industrial building + wood frame office area. Future permit required to complete and occupy all suites. Water curtain equivalency by GHL for 2 hr non-combustible construction spatial separation requirements for East and West building face, for number of opening in North East building face and combustible construction within 1.2m of property line. One 3/4 hr demising wall dividing 425.9m2 suite from remainder of building. Structural drawings in foundation permit BP110375. Part 3 - 1324m2 building BCBC1998 3.2.2.72., F-2 occupancy with subsidiary D, sprinklered with fire alarm system, combustible construction, 3/4 hr floor assemblies and supports if of combustible construction. Oct. 02, 06 Plumbing for unit 100 added to this permit. Fees paid. VS |
| Application Status: | COMPLETED |
| Permit Value: | $480,000.00 |
| Builder: | WINDLEY INVESTMENTS LTD |
| Issued Date: | August 18, 2006 |
| File Close Date: | April 26, 2007 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 2035 BOXWOOD ROAD | I3 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
|
SANITARY CONNECTION
Pipe and connection must be visible for inspection. |
PARTIAL |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
FAILED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
|
PAPER/FLASHING/WATERPROOFING
When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco. |
PASSED |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
FAILED |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
FAILED |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
|
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PASSED |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PASSED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
FAILED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
FAILED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
| OCCUPANCY-OLD | PARTIAL |
| OCCUPANCY-OLD |
PASSED
2007-04-26 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)