BP110066 - 1 - 2535 McCullough Road - SCANNED

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP110066 - 1 - 2535 McCullough Road - SCANNED
Neighbourhood: Northfield    
Street Address: 1 - 2535 McCullough Road - SCANNED
Type of Application: Leasehold Improvements
File Number: BP110066
Date Application Submitted: April 07, 2006
Application Description: Unit 1 - combined units 1 and 2
1 hr. FRR/FS demising wall under building permit bp108959. Main floor = 196.2m2. Office areas subsidiary to the F2. Mezzanine= 64.55m2 = 32.9% less than 40% permitted. Visually open to below. Travel distance met. Providing two washrooms one is a toilet room for persons with disabilities. No rating required for the mezzanine.

X reference bp108959. Building Classification BCBC1998 - 3.2.2.72. F2 up to 2 storeys, sprinklered with fire alarm system, combustible or non-combustible construction, for combustible floor assemblies 3/4 hr fire separation & supports required. No rating required for mezzanines or roof.
Application Status: COMPLETED
Permit Value: $30,000.00
Building Area: 260.75 M2
2,806.69 ft2
Builder: WESTMARK CONSTRUCTION LTD
Issued Date: June 09, 2006
File Close Date: March 20, 2007

Process Steps

Task Status
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

CANCELLED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visible for inspection.

PARTIAL
FRAMING

Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval.

FAILED
FRAMING

Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval.

PASSED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PASSED
PLUMBING FINAL-OLD

All fixtures must be in place.

PARTIAL
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

FAILED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PASSED
FINAL-OLD

Final Approval as per requirements on plans.

FAILED
FINAL-OLD

Final Approval as per requirements on plans.

PASSED

2007-03-20

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.