BP109869 - 278 Selby -- Drawings Scanned/Attached

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP109869 - 278 Selby -- Drawings Scanned/Attached
Neighbourhood: Downtown/Old City    
Street Address: 278 Selby -- Drawings Scanned/Attached
Type of Application: Commercial / Multi / Industrial
File Number: BP109869
Date Application Submitted: February 17, 2006
Application Description: Oxy Liqour Store on in-ground basement with single family above. Part 9 - 141.2m2 two storeys with basement, retail / residential building, sprinklered with fire alarm system. Main floor store 141.2m2, basement store storage 90.9m2, upper floor dwelling 73.6m2. 1hr FRR/fire separation between residential and retail and 3/4 hr FRR/fire separation between retail and basement storage. 3/4 hr FRR protection for exterior deck / exit from residential unit.
Spatial construction requirements: North building face 2hr FRR and non-combustible construction for retail fire compartment; 3/4hr FRR for residential fire compartment. South building face 1hr FRR for retail fire compartment.

Aug. 9, 06 Stairs at rear changed to steel - no Fire protection required. VS
Sept. 29, 06 Areas of corners of roof to be used as closets, laundry and computer space. Washer added to plan - fee paid. VS
Application Status: COMPLETED
Permit Value: $450,000.00
Builder: RW (BOB) WALL LTD
Issued Date: May 18, 2006
File Close Date: November 15, 2006

Associated Properties

Address Zone More
278 SELBY STREET DT3 Property Report

Process Steps

Task Status
FOOTING/FORMS

Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PASSED
FOOTING/FORMS

Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PASSED
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PASSED
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PASSED
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PARTIAL
UNDERSLAB INSULATION

Inspection required prior to placing slab concrete.

CANCELLED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
PAPER/FLASHING/WATERPROOFING

When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco.

PASSED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PASSED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

FAILED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PASSED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

FAILED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

FAILED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PASSED
PLUMBING FINAL-OLD

All fixtures must be in place.

FAILED
PLUMBING FINAL-OLD

All fixtures must be in place.

PASSED
OCCUPANCY-OLD FAILED
OCCUPANCY-OLD PARTIAL
OCCUPANCY-OLD PASSED

2006-11-15

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.