BP109842 - 1050 Terminal

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP109842 - 1050 Terminal
Neighbourhood: Newcastle/Brechin    
Street Address: 1050 Terminal
Type of Application: Commercial / Multi / Industrial
File Number: BP109842
Date Application Submitted: February 10, 2006
Application Description: New gas bar/canopy, plus bldg 511m2, 96m2 parking garage, 3 CRU convenience store (E) / laundromat, (D) /restaurant (A) with parking under & 4 dwelling units over.
Part 3,Two storeys with basement plus non-combustible canopy over gas pumps. Basement area= 96m2 includes parking garage. First storey has a laundry mat, convenience store & a future restaurant, Total area first storey = 511.3m2, Second storey has 4 residential suites with an exterior exit passageway that has a 2 hr. FRR. Total area of 2nd storey 423.44m2. Bldg classification 3.2.2.26 most restrictive. Major occupancies FRR/FS; A2 to E = 2 hr FRR/FS; Group C to Group E = 2 hrs. FRR/FS, Group D to E, 1 hr. FRR/FS. 1.5 Hr FF/S btwn the basement parking storage garage F3 & the first storey. 2 hr . FRR FSS for the floor assembly btwn 1st & 2nd storey. 1 hour FRR/FS btwn the dwelling units & are to be continuous vertical separations to the under side of the roof sheathing or 1 hr rated roof.
Doreen has file Sep 16 2009

Application Status: COMPLETED
Permit Value: $1,200,000.00
Builder: MINHAS GUR
Issued Date: February 09, 2007
File Close Date: September 14, 2009

Process Steps

Task Status
FOOTING/FORMS

Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PARTIAL
FOOTING/FORMS

Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PASSED
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PARTIAL
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PASSED
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

FAILED
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

FAILED
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

FAILED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PARTIAL
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

FAILED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

FAILED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

FAILED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

FAILED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

FAILED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

FAILED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PASSED
PLUMBING FINAL-OLD

All fixtures must be in place.

FAILED
PLUMBING FINAL-OLD

All fixtures must be in place.

CANCELLED
PLUMBING FINAL-OLD

All fixtures must be in place.

PARTIAL
PLUMBING FINAL-OLD

All fixtures must be in place.

FAILED
PLUMBING FINAL-OLD

All fixtures must be in place.

PASSED
OCCUPANCY-OLD FAILED
OCCUPANCY-OLD FAILED
OCCUPANCY-OLD FAILED
OCCUPANCY-OLD PASSED

2009-09-14

FINAL-OLD

Final approval as per requirements on plans.

FAILED
FINAL-OLD

Final approval as per requirements on plans.

PARTIAL
FINAL-OLD

Final approval as per requirements on plans.

FAILED
Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.