BP109832 - 2124 Bowen -- Drawings Scanned/Attached

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP109832 - 2124 Bowen -- Drawings Scanned/Attached
Neighbourhood: Northfield    
Street Address: 2124 Bowen -- Drawings Scanned/Attached
Type of Application: Commercial / Multi / Industrial
File Number: BP109832
Date Application Submitted: February 09, 2006
Application Description: Office / Residential Building, 907.3m2, 3-storey, sprinklered with fire alarm, combustible construction. 868.6m2 parking garage on lowest floor, 755.9m2 six office suites on main floor, 907.3m2, seven dwelling units on upper floor, 24' x 26' roof patio area and 12.7m2 storage area on roof. 2hr fire separation between storage garage and office floor, 1 hr fire separation between office floor and residential floor, 3/4 hr fire separation between roof deck / storage area and residential floor. 3/4 hr fire separation between residential units and between residential units and corridor. X-reference 110290 for foundation / servicing permit. Separate permits req'd for office TI

Building Classification: 3.2.2.54. or 3.2.2.48. Group D / C occupancy, 3 storey with parking garage below as separate building. Sprinklered with fire alarm, combustible construction ok.

119.8m2 office unit #150 complete and occupy added to this permit for Mountain Vista Contracing Office. VS March 22, 07
Application Status: COMPLETED
Permit Value: $800,000.00
Builder: MOUNTAIN VISTA CONTRACTING LTD
Issued Date: September 20, 2006
File Close Date: December 07, 2007

Process Steps

Task Status
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

CANCELLED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

FAILED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

CANCELLED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

CANCELLED
PLUMBING FINAL-OLD

All fixtures must be in place.

FAILED
PLUMBING FINAL-OLD

All fixtures must be in place.

FAILED
PLUMBING FINAL-OLD

All fixtures must be in place.

PASSED
OCCUPANCY-OLD FAILED
OCCUPANCY-OLD CANCELLED
OCCUPANCY-OLD FAILED
OCCUPANCY-OLD CANCELLED
OCCUPANCY-OLD PASSED

2007-07-09

FINAL-OLD

Final approval as per requirements on plans.

FAILED
FINAL-OLD

Final approval as per requirements on plans.

PARTIAL
FINAL-OLD

Final approval as per requirements on plans.

PASSED

2007-12-07

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.