BP109795 - 1970 Island Diesel -- Drawings Scanned/Attached

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP109795 - 1970 Island Diesel -- Drawings Scanned/Attached
Neighbourhood: Northfield    
Street Address: 1970 Island Diesel -- Drawings Scanned/Attached
Type of Application: Commercial / Multi / Industrial
File Number: BP109795
Date Application Submitted: January 31, 2006
Application Description: Two storey building, with bus storage garage and office suites.

Building area (by code) = 160' x 52' = 8320 sq. ft. (772.93m2). Storage garage, Group F3 (110.5 'x 52'), 1.5hr FRR/Fire separation from 2 storeys of offices Group D (49'-6" x 52' each storey). Building classification 3.2.2.56 and 3.2.2.79 , Floor assemblies 45 min. FRR/FS and 45 min FRR for load bearing supports. Exterior wall face on east wall in the Storage garage and the office component to be 1 hr Fire resistance rating by equivalencies and water curtain sprinkler along the interior of the east exterior wall on the first and on the second storey. All ramps, stairs guards and handrails to be in compliance with 3.4. and 3.8. Future permits required for office/tenant suites. Equivalency report based on F3 storage garage and office Group D occupancies.

Jan. 16 / 06 - see comments and attach. cb
Application Status: COMPLETED
Permit Value: $350,000.00
Builder: SMITH TRANSPORTATION LTD
Issued Date: July 18, 2006
File Close Date: July 13, 2007

Associated Properties

Address Zone More
1970 ISLAND DIESEL WAY I3 Property Report

Process Steps

Task Status
FOOTING/FORMS

Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PASSED
FOOTING/FORMS

Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PASSED
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PASSED
FIRELINE

Fireline for the sprinkler system must be complete and visable for inspection.

PARTIAL
FIRELINE

Fireline for the sprinkler system must be complete and visable for inspection.

CANCELLED
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PARTIAL
UNDERSLAB INSULATION

Inspection required prior to placing slab concrete.

CANCELLED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PASSED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PASSED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PARTIAL
PLUMBING FINAL-OLD

All fixtures must be in place.

PARTIAL
PLUMBING FINAL-OLD

All fixtures must be in place.

PARTIAL
OCCUPANCY-OLD PASSED

2007-07-13

FINAL-OLD

Final approval as per requirements on plans.

FAILED
Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.