BP109760 - 19 Nicol St - Drawings Scanned/Attached

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP109760 - 19 Nicol St - Drawings Scanned/Attached
Neighbourhood: South End    
Street Address: 19 Nicol St - Drawings Scanned/Attached
Type of Application: Commercial / Multi / Industrial
File Number: BP109760
Date Application Submitted: January 18, 2006
Application Description: xref. BP 109951 for the foundation.New Hope Centre, Emergency, transitional & long-term housing.16 self-contained (dwelling) units & 8 single units, 5 double units.Group C, sprinklered (NFPA 13R), fire alarm, Building area 314 m2, 4 storeys, 2 hr non combustible firewall /1.5 hr doors between buildings,standpipes to (NFPA 14), Accessible for person with disabilities, 1 hr FRR/FS floor assemblies and 1 hr FRR load bearing bearing supports, 50 STM between dwelling /sleeping units.20 min labelled door for dwelling /sleep units only. 45 min door for 1 hr Fire separation, 1 hr FRR/FS to be continuous to the underside of the roof deck or to the underside of a one hour Fire separation for the roof assembly. 1 hr FRR/FS public corridor, 1hr FRR/FS exits, listed fire stops and fire dampers required for penetration through fire separations. Exposed building faces north elevation 1hr FRR non-combustibles plus equivalencies for elevator opening into exit lobby and for glazing in public corridor.
Application Status: COMPLETED
Permit Value: $1,840,000.00
Builder: R W (BOB) WALL CONTRACTING LTD
Issued Date: March 21, 2006
File Close Date: March 14, 2007

Associated Properties

Address Zone More
19 NICOL STREET DT4 Property Report

Process Steps

Task Status
WATER CONNECTION

Pipe and connection must be visible for inspection.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

CANCELLED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PASSED
PLUMBING FINAL-OLD

All fixtures must be in place.

PASSED
OCCUPANCY-OLD PASSED

2007-03-14

FINAL-OLD

Final approval as per requirements on plans.

CANCELLED
FINAL-OLD

Final approval as per requirements on plans.

FAILED
Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.