BP109417 - 1770 Montana

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP109417 - 1770 Montana
Neighbourhood: Chase River    
Street Address: 1770 Montana
Type of Application: Single / Two Family Dwelling
File Number: BP109417
Date Application Submitted: October 14, 2005
Application Description: For construction of a two story single family dwelling on a slab with an unfinished basement with an attached two car garage.
Application Status: COMPLETED
Building Area: 130.40 M2
1,403.61 ft2
Builder: G M K CONTRACTING LTD
Issued Date: November 25, 2005
File Close Date: May 10, 2006

Associated Properties

Address Zone More
1770 MONTANA ROAD R5 Property Report

Process Steps

Task Status
FOOTING / FORMS

Inspection of forms prior to any concrete being poured

PASSED
PERIMETER DRAIN

For perimeter drain , foundation walls should be damp proofed and drain tile in place with drain rock covering

PASSED
UNDERSLAB PLUMBING

Complete underslab plumbing must be visible

PASSED
STORM CONNECTION

Pipe and Connection must be visible for inspection

FAILED
STORM CONNECTION

Pipe and Connection must be visible for inspection

FAILED
STORM CONNECTION

Pipe and Connection must be visible for inspection

PASSED
SANITARY CONNECTION

Pipe and Connection must be visible for inspection

FAILED
SANITARY CONNECTION

Pipe and Connection must be visible for inspection

FAILED
SANITARY CONNECTION

Pipe and Connection must be visible for inspection

PASSED
WATER CONNECTION

Pipe and Connection must be visable for inspection

FAILED
WATER CONNECTION

Pipe and Connection must be visable for inspection

FAILED
WATER CONNECTION

Pipe and Connection must be visable for inspection

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping

FAILED
FRAMING

Rough in plumbing and electrical must be complete. Survey Certificate & Truss Layouts required for approval

FAILED
FRAMING

Rough in plumbing and electrical must be complete. Survey Certificate & Truss Layouts required for approval

PASSED
FRAMING

Rough in plumbing and electrical must be complete. Survey Certificate & Truss Layouts required for approval

FAILED
OCCUPANCY-OLD

Exterior of house must be complete including stairs, decks, handrails, porches and exterior finish

FAILED
OCCUPANCY-OLD

Exterior of house must be complete including stairs, decks, handrails, porches and exterior finish

PASSED

2006-05-10

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.