BP109252 - 750 Third St -- Scanned

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP109252 - 750 Third St -- Scanned
Neighbourhood: University District    
Street Address: 750 Third St -- Scanned
Type of Application: Commercial / Multi / Industrial
File Number: BP109252
Date Application Submitted: August 23, 2005
Application Description: New Nanaimo Ice Centre (Twin Arena) Main floor area 5460m2, mezzanine 1004m2. 1 hr fire separation between mezzanines 3 exits and the remainder of the building, fire rated shutters protect exit stair #3 from window openings; 1.5 hr fire separation at Zamboni storage area; 1 hr fire separation at mechanical room, refridgeration room and 2 storage rooms; 2 hr fire separation at elevator and adjoining machine room. Occupant load 722 on mezzanine, 209 on main floor, total 931.

Building classification A-3 - 3.2.2.29 sprinklered with fire alarm, non-combustible construction, floor assemblies 2 hr fire separation, mezzanines 1 hr FRR., load bearing supports FRR as required for assemblies.

Oct. 28, 05 Required Equivalency Report for exit width received and accepted. VS
Application Status: COMPLETED
Permit Value: $8,340,000.00
Builder: TASK CONSTRUCTION MANAGEMENT INC
Issued Date: October 24, 2005
File Close Date: February 12, 2009

Associated Properties

Address Zone More
750 THIRD STREET PRC1 , PRC3 Property Report

Process Steps

Task Status
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PARTIAL
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

FAILED
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PARTIAL
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PARTIAL
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PARTIAL
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PARTIAL
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PARTIAL
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

CANCELLED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PARTIAL
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

FAILED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PASSED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

SCHEDULED
OCCUPANCY-OLD CANCELLED
OCCUPANCY-OLD CANCELLED
OCCUPANCY-OLD CANCELLED
OCCUPANCY-OLD PARTIAL
OCCUPANCY-OLD PASSED

2006-10-31

OCCUPANCY-OLD PASSED

2009-02-12

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.