BP109062 - 1273 Island Hwy S (Bldg A) (Parent = 1275 Island Hwy S) -- Drawings Scanned/Attached
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP109062 - 1273 Island Hwy S (Bldg A) (Parent = 1275 Island Hwy S) -- Drawings Scanned/Attached | |
|---|---|
| Neighbourhood: | Harewood |
| Street Address: | 1273 Island Hwy S (Bldg A) (Parent = 1275 Island Hwy S) -- Drawings Scanned/Attached |
| Type of Application: | Commercial / Multi-Res Alteration |
| File Number: | BP109062 |
| Date Application Submitted: | July 13, 2005 |
| Application Description: |
added patio does not increase occupant load ensure h/c/ accessible recalculated occupant load to 150 patrons on February 2, 2006 installed panic hardware on exits doors , Fire department posted OL on February 2, 2006 DVP00090 varied parking by 36 parking stalls to accommodate a 150- seat pub. Chase River Arms Pub : Group A, Division 2, 290m2 , Occupant Load 65 patrons, 2 exits, 2 hr. fire separation /fire resistance rating between this unit and Group E adjacent Unit. New kitchen with kitchen exhaust to NFPA 96 , providing new washroom for persons with disablilites and female washroom with 3 water closets and male washroom with 1 water closet/1 urinal. Existing Building. "A" 15022 sq ft, one storey, non-combustible roof , sprinklered, without fire alarm, building. (3.2.2.21, 1992 BCBC and 3.2.2.25, 1998 BCBC ); |
| Application Status: | COMPLETED |
| Permit Value: | $60,000.00 |
| Building Area: |
290.00 M2 3,121.53 ft2 |
| Builder: | VIA CONTRACTING LTD |
| Issued Date: | August 04, 2005 |
| File Close Date: | November 23, 2005 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 1275 ISLAND HIGHWAY S | CC3 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PASSED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
CANCELLED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
FAILED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
FAILED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PARTIAL |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
|
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
CANCELLED |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
FAILED |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PARTIAL |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
FAILED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
FAILED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PARTIAL |
|
FINAL-OLD
Final approval as per requirements on plans. |
FAILED |
|
FINAL-OLD
Final approval as per requirements on plans. |
PASSED
2005-11-23 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)