BP108730 - 2517 Bowen

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP108730 - 2517 Bowen
Neighbourhood: Diver Lake    
Street Address: 2517 Bowen
Type of Application: Commercial / Multi-Res Alteration
File Number: BP108730
Date Application Submitted: May 04, 2005
Application Description: Co-op Building - Enlarging existing enclosed mezzanine (C.R.U. - C), Dividing space for 7 leasehold occupancies, 5 "E" occupancies, 1 "A-2" occupancy, 1 "F-2" occupancy. Work includes 10 new washrooms, one "accessible" washroom in each suite, sprinkler changes, new exits, stairs from mezzanines and interior demising walls. Leasehold improvements under this permit include:
C.R.U. - A - 244.3m2 Co-op Garden Centre, retail occupancy
C.R.U. - B - 623.4m2 Pro Golf Centre, retail occupancy
C.R.U. - C - 302.5m2 Co-op Offices, office occupancy
C.R.U. - D - 1723.85m2 Liquidation World, retail occupancy
Remainder of leasehold spaces require future permits to complete and occupy.
Existing building 4191m2 -BCBC1998 3.2.2.60. "E" One storey combustible & non-combustible construction, 45min. FRR for mezzanines and supporting structures if combustible construction, sprinklered with fire alarm system, with new equivalency for size of enclosed (separate suite) office mezzanine in CRU - D.
Application Status: COMPLETED
Permit Value: $200,000.00
Builder: ISLAND WEST COAST DEVELOPMENTS
Issued Date: June 22, 2005
File Close Date: May 24, 2006

Process Steps

Task Status
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PARTIAL
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PARTIAL
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

CANCELLED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PASSED
PLUMBING FINAL-OLD

All fixtures must be in place.

PARTIAL
PLUMBING FINAL-OLD

All fixtures must be in place.

PASSED
FINAL-OLD

Final approval as per requirements on plans.

PARTIAL
FINAL-OLD

Final approval as per requirements on plans.

PARTIAL
FINAL-OLD

Final approval as per requirements on plans.

FAILED
FINAL-OLD

Final approval as per requirements on plans.

PASSED

2006-05-24

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.