BP108730 - 2517 Bowen
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP108730 - 2517 Bowen | |
|---|---|
| Neighbourhood: | Diver Lake |
| Street Address: | 2517 Bowen |
| Type of Application: | Commercial / Multi-Res Alteration |
| File Number: | BP108730 |
| Date Application Submitted: | May 04, 2005 |
| Application Description: |
Co-op Building - Enlarging existing enclosed mezzanine (C.R.U. - C), Dividing space for 7 leasehold occupancies, 5 "E" occupancies, 1 "A-2" occupancy, 1 "F-2" occupancy. Work includes 10 new washrooms, one "accessible" washroom in each suite, sprinkler changes, new exits, stairs from mezzanines and interior demising walls. Leasehold improvements under this permit include: C.R.U. - A - 244.3m2 Co-op Garden Centre, retail occupancy C.R.U. - B - 623.4m2 Pro Golf Centre, retail occupancy C.R.U. - C - 302.5m2 Co-op Offices, office occupancy C.R.U. - D - 1723.85m2 Liquidation World, retail occupancy Remainder of leasehold spaces require future permits to complete and occupy. Existing building 4191m2 -BCBC1998 3.2.2.60. "E" One storey combustible & non-combustible construction, 45min. FRR for mezzanines and supporting structures if combustible construction, sprinklered with fire alarm system, with new equivalency for size of enclosed (separate suite) office mezzanine in CRU - D. |
| Application Status: | COMPLETED |
| Permit Value: | $200,000.00 |
| Builder: | ISLAND WEST COAST DEVELOPMENTS |
| Issued Date: | June 22, 2005 |
| File Close Date: | May 24, 2006 |
Process Steps
| Task | Status |
|---|---|
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PARTIAL |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PARTIAL |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
CANCELLED |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PASSED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PARTIAL |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
|
FINAL-OLD
Final approval as per requirements on plans. |
PARTIAL |
|
FINAL-OLD
Final approval as per requirements on plans. |
PARTIAL |
|
FINAL-OLD
Final approval as per requirements on plans. |
FAILED |
|
FINAL-OLD
Final approval as per requirements on plans. |
PASSED
2006-05-24 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)