BP108696 - #2 - 5769 Turner Road
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP108696 - #2 - 5769 Turner Road | |
|---|---|
| Neighbourhood: | Rutherford |
| Street Address: | #2 - 5769 Turner Road |
| Type of Application: | Leasehold Improvements |
| File Number: | BP108696 |
| Date Application Submitted: | April 28, 2005 |
| Application Description: |
Expand existing 278.5m2 Blue Ginger Restaurant into 91.6m2 adjoining tenant space to become a Lounge for the restaurant. New total area 370.1m2. Work consists of adding 4 & moving 2 hand wash sinks and adding dishwasher in new counter, three openings into existing space, completing 1 hr. fire separation of existing demising wall to underside of roof. No sprinkler changes. Existing (Building "F") 778.5m2 sprinklered, combustible construction, no fire alarm. Classified under 1998 BCBC - 3.2.2.28 A-2 combustible or non-combustible construction, facing two streets, maximum size 1000m2 if divided into 1hr fire compartments not exceeding 500m2 in size. Occupant Load - 150 persons in restaurant / lounge, 60 persons on patio. Total maximum occupant load of restaurant, lounge and patio is 150 persons. |
| Application Status: | COMPLETED |
| Permit Value: | $30,000.00 |
| Building Area: |
91.30 M2 982.74 ft2 |
| Issued Date: | August 22, 2005 |
| File Close Date: | March 23, 2006 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 5801 TURNER ROAD | CC3 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible. |
CANCELLED |
|
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible. |
PASSED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
CANCELLED |
|
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PARTIAL |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PARTIAL |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
|
FINAL-OLD
Final Approval as per requirements on plans. |
FAILED |
|
FINAL-OLD
Final Approval as per requirements on plans. |
CANCELLED |
|
FINAL-OLD
Final Approval as per requirements on plans. |
FAILED |
|
FINAL-OLD
Final Approval as per requirements on plans. |
PASSED
2006-03-23 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)