BP108571 - 1950 Bollinger

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP108571 - 1950 Bollinger
Neighbourhood: Northfield    
Street Address: 1950 Bollinger
Type of Application: Commercial / Multi / Industrial
File Number: BP108571
Date Application Submitted: April 01, 2005
Application Description: New "F2" multi - tenant warehouse - 427m2 first storey, 51.3m2 second floor and 53.4m2 separate second floor in non-combustible shell, sprinklered with fire alarm system. 3/4 hr fire separation, FRR required between suites. Construction requirements for spatial separation for South and East wall, non-combustible construction with non-combustible cladding, 2 hr FRR. An equivalency by GLH Consultants for the 2hr FRR is provided with water curtains above and below the second floor. Future permit required to complete and occupy the separate suites. Two "accessible" washrooms to be completed plus rough-in for two washrooms. Sept. 26,05 water curtain was not installed in office below main floor, additional equivalency report covers this small office area. The exterior office wall will be protected with tightly fitted mineral wool, 2 layers 5/8 type x drywall, plus the office is constructed as a fire separation with a rated door. VS
Nov. 25, 05 - 2nd floor deleted on right side. VS
Application Status: COMPLETED
Permit Value: $225,600.00
Builder: L D C MANAGEMENT LTD
Issued Date: May 12, 2005
File Close Date: February 13, 2006

Associated Properties

Address Zone More
1950 BOLLINGER ROAD I3 Property Report

Process Steps

Task Status
FOOTING/FORMS

Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PASSED
FOOTING/FORMS

Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

CANCELLED
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PASSED
FIRELINE

Fireline for the sprinkler system must be complete and visable for inspection.

PASSED
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

CANCELLED
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PARTIAL
STORM CONNECTION

Pipe and connection must be visible for inspection.

CANCELLED
STORM CONNECTION

Pipe and connection must be visible for inspection.

PASSED
SANITARY CONNECTION

Pipe and connection must be visible for inspection.

CANCELLED
SANITARY CONNECTION

Pipe and connection must be visible for inspection.

PASSED
WATER CONNECTION

Pipe and connection must be visible for inspection.

CANCELLED
WATER CONNECTION

Pipe and connection must be visible for inspection.

PASSED
WATER CONNECTION

Pipe and connection must be visible for inspection.

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

FAILED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PARTIAL
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

FAILED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PASSED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PASSED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

FAILED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PARTIAL
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PASSED
PLUMBING FINAL-OLD

All fixtures must be in place.

PASSED
OCCUPANCY-OLD CANCELLED
OCCUPANCY-OLD CANCELLED
OCCUPANCY-OLD FAILED
OCCUPANCY-OLD PASSED

2006-02-13

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.