BP108511 - 203 - 6750 Island Highway -- Drawings Scanned/Attached
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP108511 - 203 - 6750 Island Highway -- Drawings Scanned/Attached | |
|---|---|
| Neighbourhood: | Dover |
| Street Address: | 203 - 6750 Island Highway -- Drawings Scanned/Attached |
| Type of Application: | Leasehold Improvements |
| File Number: | BP108511 |
| Date Application Submitted: | March 15, 2005 |
| Application Description: |
Yoshi Sushi Restaurant 216.8m2 - Improvements consist of adding 2 sinks in Sushi bar and mop sink in staff washroom. Moving existing handsink, pot sinks, dishwasher and wash down sink against rear wall. Replacing existing mop sink with ice machine. Interior millwork, new ceiling, partitian wall changes. 4 sprinkler heads moved, 3 new sprinkler heads. Existing 2 hr FRR / fire separation demising walls between units to remain, previous tenant was restaurant, A-2 occupancy. Maximum occupant load for Food Primary Liquor Licensing 89 patrons. 1189.12 m2 building "B" one storey, sprinklered with fire alarm. Reclassified under BCBC1998 as 3.2.2.27. - A2 One storey , sprinklered, combustible or non-combustible construction. |
| Application Status: | COMPLETED |
| Permit Value: | $160,000.00 |
| Building Area: |
216.80 M2 2,333.61 ft2 |
| Builder: | BUCK ISLAND CONSTRUCTION LTD |
| Issued Date: | April 07, 2005 |
| File Close Date: | May 27, 2005 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 6750 ISLAND HIGHWAY N | CC4 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible. |
PARTIAL |
|
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible. |
PASSED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
FAILED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
PASSED |
|
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PARTIAL |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
FAILED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
FAILED |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PASSED |
|
FINAL-OLD
Final Approval as per requirements on plans. |
FAILED |
|
FINAL-OLD
Final Approval as per requirements on plans. |
CANCELLED |
|
FINAL-OLD
Final Approval as per requirements on plans. |
PASSED
2005-05-27 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)