BP108185 - 1533 Estevan - units 5, 6 &4b -- Drawings Scanned/Attached
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP108185 - 1533 Estevan - units 5, 6 &4b -- Drawings Scanned/Attached | |
|---|---|
| Neighbourhood: | Newcastle/Brechin |
| Street Address: | 1533 Estevan - units 5, 6 &4b -- Drawings Scanned/Attached |
| Type of Application: | Commercial / Multi-Res Alteration |
| File Number: | BP108185 |
| Date Application Submitted: | November 23, 2004 |
| Application Description: |
Expansion of Bank of Montreal - add 133.32m2 previous unit 4b to make 517.74m2 "D" occupancy. Remove existing 8" hollow concrete block non-conforming 2 hr firewall between unit 5 and unit 4b. Replace with non-combustible 2 hr firewall equivalency by GHL Consultants Ltd. between Bank of Montreal and unit 4a. Equivalency to replace the existing block firewall does not make the building comply with 1998 BCBC but provides an equivalent or better protection than the firewall it replaces. Existing 1957 building, combustible, unsprinklered, 2892.8m2 building with partial Firewall (non-conforming) between West unit 12 (1295m2) and remainder of building; centre area (601m2) now divided from 996.58m2 East side by 2 hr Firewall (created under equivalency). |
| Application Status: | COMPLETED |
| Permit Value: | $650,000.00 |
| Building Area: |
517.74 M2 5,572.90 ft2 |
| Builder: | P C L CONSTRUCTORS CANADA INC |
| Issued Date: | February 10, 2005 |
| File Close Date: | June 10, 2005 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 1533 ESTEVAN ROAD | CC3 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
CANCELLED |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PASSED |
|
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
|
FINAL-OLD
Final approval as per requirements on plans. |
PASSED
2005-06-10 |
|
FINAL-OLD
Final approval as per requirements on plans. |
PASSED
2005-06-21 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)