BP108134 - 5291 Rutherford - (parent address 5941 Nelson Rd) -- Drawings Scanned/Attached

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP108134 - 5291 Rutherford - (parent address 5941 Nelson Rd) -- Drawings Scanned/Attached
Neighbourhood: Rutherford    
Street Address: 5291 Rutherford - (parent address 5941 Nelson Rd) -- Drawings Scanned/Attached
Type of Application: Commercial / Multi / Industrial
File Number: BP108134
Date Application Submitted: November 12, 2004
Application Description: New 140.4m2 - 3.2.2.28. Group A-2 , one storey, combustible construction, sprinklered by bylaw. A-2 occupancy Tenant complete and occupy for Gardensweet Cottage Restaurant included under this permit . One male/unisex accessible washroom and two female toilets provided. Occupant load 46, travel distance max. 30m with 2 exits required.
45minute FRR required at all exterior walls for spatial separation. East side 3.6m setback required to allow combustible cladding.
On-site servicing for this building and 3 future buildings included on this building permit.
Application Status: COMPLETED
Permit Value: $100,000.00
Builder: DUECK GENERAL CONTRACTING
Issued Date: February 10, 2005
File Close Date: September 19, 2005

Associated Properties

Address Zone More
5291 RUTHERFORD ROAD CC1 Property Report

Process Steps

Task Status
FOOTING/FORMS

Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PASSED
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PASSED
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PARTIAL
STORM CONNECTION

Pipe and connection must be visible for inspection.

PASSED
SANITARY CONNECTION

Pipe and connection must be visible for inspection.

PASSED
WATER CONNECTION

Pipe and connection must be visible for inspection.

FAILED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PASSED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

FAILED
OCCUPANCY-OLD FAILED
OCCUPANCY-OLD FAILED
OCCUPANCY-OLD PASSED

2005-09-19

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.