BP107979 - 3987 Valewood Dr

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP107979 - 3987 Valewood Dr
Neighbourhood: Pleasant Valley    
Street Address: 3987 Valewood Dr
Type of Application: Locate Permit
File Number: BP107979
Date Application Submitted: September 29, 2004
Application Description: to locate 25' x 52' double wide manufactured home on concrete foundations with crawlspace and to construct attached 16' x 20' single garage.

MHR#90115
CSA#51301
SER#2937

Physical File Scanned + attached Jul 8, 2009 db
Application Status: RETIRED
Permit Value: $11,000.00
Building Area: 116.17 M2
1,250.44 ft2
Builder: RETIRE WEST COMMUNITIES LTD
Issued Date: November 05, 2004
File Close Date: October 26, 2010

Associated Properties

Address Zone More
3950 BIGGS ROAD AR1 , R12 Property Report
3987 VALEWOOD DRIVE R12 Property Report

Process Steps

Task Status
FOOTING/FORMS

Inspection of Forms prior to any cement being poured. For Footing inspection, forms must be complete and approved plans (complete with City Stamp) must be onsite.

FAILED
FOOTING/FORMS

Inspection of Forms prior to any cement being poured. For Footing inspection, forms must be complete and approved plans (complete with City Stamp) must be onsite.

PASSED
PERIMETER DRAIN

For Perimeter Drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

FAILED
PERIMETER DRAIN

For Perimeter Drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PASSED
PERIMETER DRAIN

For Perimeter Drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

FAILED
PERIMETER DRAIN

For Perimeter Drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PASSED
LATERAL BRACING & SHEATHING

All nailing and blocking associated with braced wall panels to be completed for this inspection. Wood-based interior braced wall panels to be sheathed. Exterior braced wall panel locations to be clearly marked out on the interior and exterior. Interior braced wall panels to be clearly marked so their location can be seen now and later at the time of INTERIOR BRACED WALL PANEL INSPECTION. Additional anchor bolts shall be installed two per braced wall panel where a building contains framed walls supporting more than two floors.

FAILED
LATERAL BRACING & SHEATHING

All nailing and blocking associated with braced wall panels to be completed for this inspection. Wood-based interior braced wall panels to be sheathed. Exterior braced wall panel locations to be clearly marked out on the interior and exterior. Interior braced wall panels to be clearly marked so their location can be seen now and later at the time of INTERIOR BRACED WALL PANEL INSPECTION. Additional anchor bolts shall be installed two per braced wall panel where a building contains framed walls supporting more than two floors.

PASSED
Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.