BP107790 - 1721 Fleet Place

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP107790 - 1721 Fleet Place
Neighbourhood: Northfield    
Street Address: 1721 Fleet Place
Type of Application: Commercial / Multi / Industrial
File Number: BP107790
Date Application Submitted: August 06, 2004
Application Description: New Warehouse : Part 3 Building (Pre-fabricated engineered building), Group F, Division 2, One stories, Building Classification 3.2.2.69, Area = 795.5m2, sprinklered(by bylaw), fire alarm, accessible. 45 min. FS to create two CRU's. North CRU (unit B) has two storey offices, accessible washroom. Floor assemblies 45min. FS, loadbearing 45 min FRR, 45 min FS for wall assemblies separating the warehouse/office. South CRU has 1 hr FS between office & warehouse as required by equivalency, Rated exit (1 hr FS) required and exterior wall 1 hr FRR. And south CRU has rough-in plumbing only. West & south exposed building faces (Group F2)= 2hr FRR. Equivalency report provided by GHL Consultants for sprinkler protection in lieu of physical protection for the exterior walls in the Group F2, South wall and above office south wall and West (2hr.FRR) and North (1hr. FRR)
Note: North office has 0hr FRR exterior wall.
Application Status: COMPLETED
Permit Value: $388,000.00
Builder: FLEET VENTURES LTD
Issued Date: September 20, 2004
File Close Date: December 11, 2007

Associated Properties

Address Zone More
1721 FLEET PLACE I1 Property Report

Process Steps

Task Status
FOOTING/FORMS

Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PARTIAL
FOOTING/FORMS

Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PARTIAL
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PARTIAL
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PARTIAL
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PASSED
FIRELINE

Fireline for the sprinkler system must be complete and visable for inspection.

PARTIAL
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PASSED
PAPER/FLASHING/WATERPROOFING

When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco.

PASSED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

FAILED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PASSED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PARTIAL
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PASSED
PLUMBING FINAL-OLD

All fixtures must be in place.

PASSED
OCCUPANCY-OLD CANCELLED
FINAL-OLD

Final approval as per requirements on plans.

FAILED
FINAL-OLD

Final approval as per requirements on plans.

PARTIAL
FINAL-OLD

Final approval as per requirements on plans.

PASSED

2007-12-11

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.