Application Description: Interior renovations only in existing building.
Existing building 225m2, two storeys with small basement, unsprinklered. Part 9 building.
First storey, Group E, Second storey Group D, no change of use, adding new fire alarm system per Equivalency report by A. Harmsworth, P.Eng.; adding 45min Fire separation for the public corridor on the second floor, 20 min. minimum door assembly and self closing devices. 45 min fire separation/resistance rating of the stair separating the first storey and the second storey. Upgrade to the floor assembly at the underside of the existing 2 x 10 wood joists for a fire resistance rating of 45min. listed assembly. Existing steel beams/plaster code compliance for 45min FRR by A. Harmsworth, P.Eng. The Main Floor - Group E shall not have more than 10 seats. Adding accessible washroom. Stairs/guards/handrails to comply with code. Equivalency report by A. Harmsworth, P.Eng. for single Exit from second storey, adding fire alarm system as equivalent.

Application Status: COMPLETED
Permit Value: $50,000.00
Building Area: 450.00 M2
4,843.76 ft2
Issued Date: October 01, 2004
File Close Date: September 05, 2006

Associated Properties

Address Zone More
499 WALLACE STREET DT7 Property Report

Process Steps

Task Status
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

FAILED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

FAILED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

CANCELLED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

FAILED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

CANCELLED
PLUMBING FINAL-OLD

All fixtures must be in place.

FAILED
PLUMBING FINAL-OLD

All fixtures must be in place.

PARTIAL
PLUMBING FINAL-OLD

All fixtures must be in place.

FAILED
PLUMBING FINAL-OLD

All fixtures must be in place.

PARTIAL
PLUMBING FINAL-OLD

All fixtures must be in place.

PASSED
FINAL-OLD

Final approval as per requirements on plans.

FAILED
FINAL-OLD

Final approval as per requirements on plans.

FAILED
FINAL-OLD

Final approval as per requirements on plans.

CANCELLED
FINAL-OLD

Final approval as per requirements on plans.

FAILED
FINAL-OLD

Final approval as per requirements on plans.

FAILED
FINAL-OLD

Final approval as per requirements on plans.

PASSED

2006-09-05

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.