BP107473 - 1602 Northfield -- Drawings Scanned/Attached
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP107473 - 1602 Northfield -- Drawings Scanned/Attached | |
|---|---|
| Neighbourhood: | Northfield |
| Street Address: | 1602 Northfield -- Drawings Scanned/Attached |
| Type of Application: | Commercial / Multi-Res Alteration |
| File Number: | BP107473 |
| Date Application Submitted: | May 19, 2004 |
| Application Description: |
National Car & Truck Sales Ltd - Dealership building - Work consists of architectural feature front and back, stairwell reconfiguration, moving 4 plumbing fixtures, adding 2, adding beams and footings where walls are removed. Workshop building - 230m2 Work consists of architectural feature front and back. New windows within existing openings and new siding done under BP107663 Dealership Building classification - 181.2m2 Part 9 - F3 on main floor with C above, 1 hr FRR fire separation required in area's being renovated. |
| Application Status: | COMPLETED |
| Permit Value: | $25,000.00 |
| Builder: | ISLAND WEST COAST DEVELOPMENTS |
| Issued Date: | August 24, 2004 |
| File Close Date: | December 09, 2004 |
Process Steps
| Task | Status |
|---|---|
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PASSED |
|
PAPER/FLASHING/WATERPROOFING
When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco. |
PASSED |
|
PAPER/FLASHING/WATERPROOFING
When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco. |
CANCELLED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PASSED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
|
FINAL-OLD
Final approval as per requirements on plans. |
FAILED |
|
FINAL-OLD
Final approval as per requirements on plans. |
PASSED
2004-12-09 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)