BP107353 - 92-3200 Island Hwy

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP107353 - 92-3200 Island Hwy
Neighbourhood: Rutherford    
Street Address: 92-3200 Island Hwy
Type of Application: Leasehold Improvements
File Number: BP107353
Date Application Submitted: April 28, 2004
Application Description: Quizno's - Group A-2 - 105m2 tenant improvement, sprinkler changes, interior millwork, installation of two accessible toilet rooms with 5 fixtures, installation of 5 kitchen plumbing fixtures and HWT. Demising wall (right side) to have 1 layer of 5/8" type X drywall added to complete the 2 hr FRR fire separation required. Existing 2 hr FRR at floor/ceiling between suite and SaveOnFood mezzanine, supporting columns to have 2 hr FRR.
Building Classification 3.2.2.57, Group E, noncombustible construction, sprinklered, fire alarm.
Application Status: COMPLETED
Permit Value: $60,000.00
Building Area: 105.00 M2
1,130.21 ft2
Issued Date: June 08, 2004
File Close Date: August 25, 2004

Associated Properties

Address Zone More
3200 ISLAND HIGHWAY N CC3 Property Report

Process Steps

Task Status
UNDERSLAB PLUMBING

Complete underslab plumbing must be visible.

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visible for inspection.

FAILED
FRAMING

Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval.

PASSED
PLUMBING FINAL-OLD

All fixtures must be in place.

CANCELLED
PLUMBING FINAL-OLD

All fixtures must be in place.

FAILED
PLUMBING FINAL-OLD

All fixtures must be in place.

FAILED
PLUMBING FINAL-OLD

All fixtures must be in place.

PARTIAL
PLUMBING FINAL-OLD

All fixtures must be in place.

PASSED
PLUMBING FINAL-OLD

All fixtures must be in place.

SCHEDULED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

FAILED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

FAILED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

FAILED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PASSED
FINAL-OLD

Final Approval as per requirements on plans.

CANCELLED
FINAL-OLD

Final Approval as per requirements on plans.

FAILED
FINAL-OLD

Final Approval as per requirements on plans.

FAILED
FINAL-OLD

Final Approval as per requirements on plans.

PASSED

2004-08-25

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.