BP107275 - 5777 Turner Road -- Drawings Scanned/Attached
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP107275 - 5777 Turner Road -- Drawings Scanned/Attached | |
|---|---|
| Neighbourhood: | Rutherford |
| Street Address: | 5777 Turner Road -- Drawings Scanned/Attached |
| Type of Application: | Leasehold Improvements |
| File Number: | BP107275 |
| Date Application Submitted: | April 08, 2004 |
| Application Description: |
TD Canada Trust - existing tenant expanding into remainder of building on both floors 790m2 area total. Work includes adding interior stair between upper and lower level, sprinkler changes, adding washrooms and sinks in upper floor, adding exterior window and millwork. Group "D" occupancy building 465m2 two storey sprinklered (by bylaw) combustible building . 325m2 upper floor, Floor assembly fire separation and supporting structure 45min FRR . New (secondary) stairwell considered interconnected floor area as per 3.2.8.2.(6) BCBC no fire separation required. |
| Application Status: | COMPLETED |
| Permit Value: | $300,000.00 |
| Building Area: |
462.00 M2 4,972.92 ft2 |
| Builder: | SUMMIT BROOKE DEVELOPMENTS CORP |
| Issued Date: | May 05, 2004 |
| File Close Date: | September 29, 2004 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 5801 TURNER ROAD | CC3 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
CANCELLED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
PARTIAL |
|
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PARTIAL |
|
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
CANCELLED |
|
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PASSED |
|
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
FAILED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
FAILED |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PARTIAL |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PARTIAL |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
FAILED |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PASSED |
|
FINAL-OLD
Final Approval as per requirements on plans. |
PARTIAL |
|
FINAL-OLD
Final Approval as per requirements on plans. |
PASSED
2004-09-29 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)