BP107169 - 19 Nicol -- Drawings Scanned/Attached
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP107169 - 19 Nicol -- Drawings Scanned/Attached | |
|---|---|
| Neighbourhood: | South End |
| Street Address: | 19 Nicol -- Drawings Scanned/Attached |
| Type of Application: | Leasehold Improvements |
| File Number: | BP107169 |
| Date Application Submitted: | March 11, 2004 |
| Application Description: |
Salvation Army - Voluntary upgrade to existing Building 172.5m2 - basement 300 m2 - main floor 236.5 - 2nd floor Existing A2, 3.2.2.27, 2 storeys with basement, installing new sprinkler system , reference BP107200 for sprinkler system, installing new fire alarm system, single exit from the basement and two exits from the 1st and 2nd storey are provided. 45min FS for floor assembly above basement, 45min minimum for exits. Floor assemblies between first and second storey no special requirement.Fire separation for the lobby. Building Occupant load 100 persons. |
| Application Status: | COMPLETED |
| Permit Value: | $206,000.00 |
| Builder: | RW (BOB) WALL LTD |
| Issued Date: | October 06, 2004 |
| File Close Date: | October 05, 2005 |
Process Steps
| Task | Status |
|---|---|
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
FAILED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
FAILED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
FAILED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
|
FINAL-OLD
Final Approval as per requirements on plans. |
PARTIAL |
|
FINAL-OLD
Final Approval as per requirements on plans. |
FAILED |
|
FINAL-OLD
Final Approval as per requirements on plans. |
FAILED |
|
FINAL-OLD
Final Approval as per requirements on plans. |
CANCELLED |
|
FINAL-OLD
Final Approval as per requirements on plans. |
FAILED |
|
FINAL-OLD
Final Approval as per requirements on plans. |
PASSED
2005-10-05 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)