BP106665 - 1950 Boxwood Road

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP106665 - 1950 Boxwood Road
Neighbourhood: Northfield    
Street Address: 1950 Boxwood Road
Type of Application: Commercial / Multi / Industrial
File Number: BP106665
Date Application Submitted: October 14, 2003
Application Description: Design stage acceptance recieved December 17, 2003.
approved on/off site servicing
xreference bp106854 for the foundation.
Part 3 Building (Metal building), Group F, Division 2, One storey, Building Classification 3.2.2.71, Area = 1196m2, sprinklered by bylaw. North and west exposed building faces = 2hr Fire resistance rating . Equivalency report provided by GHL Consultants for sprinkler protection in lieu of physical protection. The office space is separated from warehouse by a 1 hr FRR to create a fire compartment. The West wall within the office area is constructed as a 1 hour FRR. The electrical room within warehouse at west wall 2hr. FRR. The area above the office and the electrical room is protected with the water curtain sprinkler system described in GHL report. The area above the office and the electrical room is not permitted for storage of any kind.
Application Status: COMPLETED
Permit Value: $400,000.00
Builder: SUN GLO HOME IMPROVEMENT CENTRE LTD
Issued Date: December 12, 2003
File Close Date: July 02, 2004

Associated Properties

Address Zone More
1950 BOXWOOD ROAD I1 Property Report

Process Steps

Task Status
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PASSED
FIRELINE

Fireline for the sprinkler system must be complete and visable for inspection.

CANCELLED
FIRELINE

Fireline for the sprinkler system must be complete and visable for inspection.

PARTIAL
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PASSED
WATER CONNECTION

Pipe and connection must be visible for inspection.

CANCELLED
WATER CONNECTION

Pipe and connection must be visible for inspection.

CANCELLED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PARTIAL
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PARTIAL
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PARTIAL
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PASSED
PLUMBING FINAL-OLD

All fixtures must be in place.

PASSED
OCCUPANCY-OLD FAILED
OCCUPANCY-OLD PASSED

2004-07-08

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.