BP106539 - 1061 Maughan - scanned
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP106539 - 1061 Maughan - scanned | |
|---|---|
| Neighbourhood: | Duke Point |
| Street Address: | 1061 Maughan - scanned |
| Type of Application: | Commercial / Multi / Industrial |
| File Number: | BP106539 |
| Date Application Submitted: | August 29, 2003 |
| Application Description: |
added two sinks Jan 12, 2003, includes sprinklers throughout the building, includes found'n for leanto. Phase 1 (this permit); Relocate 2 storey office building (existing Part 9 building) to new foundation and convert use to a Group F Division 2 (medium Hazard occupancy) food processing plant on the 1st storey (194m2) and (future permit) convert the use on the second storey (179.6m2) to a caretaker dwelling unit; Group C (residential). Scope of work involves new foundation, upgrading of the existing floor system and new common lobby to a 2-hr fire separation/fire resistance rating(FRR/FS)50STM. Floor assembly required to be 2hr FS/FRR/50STM, Plumbing is noncombustible . 2-hour fire dampers on the ducts are to be provided for any penetrations within the required fire separations. Existing sprinkler system to be upgraded. accessible main floor and washroom for persons with disabilities. Separate permit required to complete and occupy the upper floor and the future addition. |
| Application Status: | COMPLETED |
| Permit Value: | $50,000.00 |
| Builder: | PRECISION CIVIL INSTALLATIONS LTD |
| Issued Date: | October 23, 2003 |
| File Close Date: | October 22, 2004 |
Process Steps
| Task | Status |
|---|---|
|
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PASSED |
|
FIRELINE
Fireline for the sprinkler system must be complete and visable for inspection. |
PASSED |
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PASSED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
CANCELLED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
FAILED |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PARTIAL |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
|
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
CANCELLED |
|
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
|
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
CANCELLED |
|
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
FAILED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
|
FINAL-OLD
Final approval as per requirements on plans. |
FAILED |
|
FINAL-OLD
Final approval as per requirements on plans. |
PASSED
2004-10-22 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)