BP106307 - 821 Maughan - SCANNED

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP106307 - 821 Maughan - SCANNED
Neighbourhood: Duke Point    
Street Address: 821 Maughan - SCANNED
Type of Application: Commercial / Multi / Industrial
File Number: BP106307
Date Application Submitted: June 23, 2003
Application Description: Part 9 building (Duke Point Auto Recyclers), Group F, Division 2, 2 storey, 45min fire separation for the floor system. 0 roof rating . 1st. storey = 1008 sq.ft.(93.6m2); 2nd storey = 524 sq ft (48.7m2);
45min FRR/FS for the exit enclosure from the upper floor. accessible, sprinklered by bylaw , no fire alarm.
Application Status: COMPLETED
Permit Value: $150,000.00
Builder: 455074 BC LTD
Issued Date: August 19, 2003
File Close Date: December 30, 2003

Associated Properties

Address Zone More
821 MAUGHAN ROAD I4 Property Report

Process Steps

Task Status
FOOTING/FORMS

Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PASSED
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PASSED
FIRELINE

Fireline for the sprinkler system must be complete and visable for inspection.

PASSED
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PASSED
STORM CONNECTION

Pipe and connection must be visible for inspection.

PASSED
SANITARY CONNECTION

Pipe and connection must be visible for inspection.

PASSED
WATER CONNECTION

Pipe and connection must be visible for inspection.

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PASSED
PAPER/FLASHING/WATERPROOFING

When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco.

PASSED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

CANCELLED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PASSED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PASSED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

FAILED
PLUMBING FINAL-OLD

All fixtures must be in place.

PASSED
OCCUPANCY-OLD FAILED
OCCUPANCY-OLD PASSED

2003-12-30

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.