BP106138 - 5-1850 Northfield
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP106138 - 5-1850 Northfield | |
|---|---|
| Neighbourhood: | Northfield |
| Street Address: | 5-1850 Northfield |
| Type of Application: | Leasehold Improvements |
| File Number: | BP106138 |
| Date Application Submitted: | May 14, 2003 |
| Application Description: |
Complete and occupy. Unit 5 Complete 45min demising wall between unit 4 and 5 , existing demising wall between 5 and 6. New 45min Fire separation between the Group D (office) (41.6m2 main floor and 41.6m2 upper floor) and the Group F2 (Warehouse) 94m2 . The Group D Occupancy complies with 9.9.4.7. 45min FRR floor rating required. Noncombustible plumbing or plumbing with fire stop system (Donuts). Single exits permitted each occupacy and the travel distance is less than the required 25m. Part 9 building, 571m2 sprinklered, fire alarm , combusible building. Existing firewall divided building into two buildings. |
| Application Status: | COMPLETED |
| Permit Value: | $10,000.00 |
| Building Area: |
135.00 M2 1,453.13 ft2 |
| Builder: | ISLAND WEST COAST DEVELOPMENTS |
| Issued Date: | June 04, 2003 |
| File Close Date: | November 21, 2003 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 5 1850 NORTHFIELD ROAD | I3 | Property Report |
| 1850 NORTHFIELD ROAD | I3 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible. |
PASSED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
PASSED |
|
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PARTIAL |
|
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PASSED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PASSED |
|
FINAL-OLD
Final Approval as per requirements on plans. |
PASSED
2003-11-21 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)