BP105595 - 6561 Island Highway -- Drawings Scanned/Attached
Neighbourhood: Dover    
Street Address: 6561 Island Highway -- Drawings Scanned/Attached
Type of Application: Commercial / Multi / Industrial
File Number: BP105595
Date Application Submitted: December 24, 2002
Application Description: received sprinklers &approved April 25,2003 by B1,B2, design and field review by S.C.Dunbar, P.Eng.

White Spot Restaurant - Group A2 - 505.7m2 - One storey -
Sprinklered, Fire alarm, 2 Exits, Occupant Load 250, Accessible, Unisex toilet room for persons with disabilities. Power operated entrance required. Ensure stairs and handrails comply with 3.4.
Building Classification = 3.2.2.27, 1998 code.

X reference BP104920 for the site servicing and the landscaping security.

May 12-added 1 basin, 1 water closet
Application Status: COMPLETED
Permit Value: $400,000.00
Builder: COLT CONSTRUCTION LTD
Issued Date: March 21, 2003
File Close Date: June 24, 2003

Associated Properties

Address Zone More
6631 ISLAND HIGHWAY N CC4 Property Report

Process Steps

Task Status
FOOTING/FORMS

Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PASSED
FIRELINE

Fireline for the sprinkler system must be complete and visable for inspection.

CANCELLED
FIRELINE

Fireline for the sprinkler system must be complete and visable for inspection.

PASSED
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

CANCELLED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PASSED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

CANCELLED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

CANCELLED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PASSED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

FAILED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

FAILED
PLUMBING FINAL-OLD

All fixtures must be in place.

CANCELLED
PLUMBING FINAL-OLD

All fixtures must be in place.

CANCELLED
PLUMBING FINAL-OLD

All fixtures must be in place.

PASSED
OCCUPANCY-OLD PASSED

2003-06-24

FINAL-OLD

Final approval as per requirements on plans.

PARTIAL
Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.