BP105292 - 2005 Boxwood

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP105292 - 2005 Boxwood
Neighbourhood: Northfield    
Street Address: 2005 Boxwood
Type of Application: Commercial / Multi / Industrial
File Number: BP105292
Date Application Submitted: October 07, 2002
Application Description: Addition added 25 x 72, and sprinklered canopy along side. added sprinkler structural and revised equivalency to permit. Feb 3, 2003.JB - Building area revised to 835m2 (see alternative solution)

Atlas Truss Building
see bp105291 for foundation permit
Building Area (BCBC) 668.9m2 plus enclosed mezzanine 65.4m2 and open mezzanine = 41 m2. Building area revised to 835m2 (see alternative solution)
Building Classification:3.2.2.71. Group F2. Accessible in public and office area. One storey. Open Mezzanine <40%, enclosed mezzanine <10%. No rating required. No fire alarm. Sprinklered by bylaw not by code. Unprotected opening permitted by code 32.8%. Building Code Equivalency Report for protection of openings and for the 1hr exposed building faces. Maximum travel distance = 30m to exit. Three required to meet travel distance. Maximum travel distance on mezzanine to egress stair 10m. (3.4.2.2.) Maximum opening in guard = 8". Mezzanine Guard height 42"on stairs 36"
Application Status: COMPLETED
Permit Value: $210,800.00
Builder: WINDLEY CONTRACTING LTD
Issued Date: November 12, 2002
File Close Date: October 03, 2003

Process Steps

Task Status
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PASSED
PAPER/FLASHING/WATERPROOFING

When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco.

PASSED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PASSED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

CANCELLED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

FAILED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

FAILED
PLUMBING FINAL-OLD

All fixtures must be in place.

CANCELLED
PLUMBING FINAL-OLD

All fixtures must be in place.

PASSED
OCCUPANCY-OLD FAILED
FINAL-OLD

Final approval as per requirements on plans.

PASSED

2003-10-03

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.