BP105185 - 6660 Mary Ellen ( Woodgrove mall site ) (parent 6631 Island Hwy) - SCANNED
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP105185 - 6660 Mary Ellen ( Woodgrove mall site ) (parent 6631 Island Hwy) - SCANNED | |
---|---|
Neighbourhood: | Dover |
Street Address: | 6660 Mary Ellen ( Woodgrove mall site ) (parent 6631 Island Hwy) - SCANNED |
Type of Application: | Commercial / Multi / Industrial |
File Number: | BP105185 |
Date Application Submitted: | September 11, 2002 |
Application Description: |
Pier 1 Imports Part 3 , Building Classification 3.2.2.62. Gross floor area 854m2, Major occupancy, Group E, One storey, sprinklered throughout, combustible construction, fire alarm. two exterior exits main floor area. one exterior exit in stock room . No rating required for roof with monitored sprinkler system. Occupant load 190. Architect reclassified building to 3.2.2.61 no fire alarm installed See other comments in tell me more. |
Application Status: | COMPLETED |
Permit Value: | $700,000.00 |
Builder: | P C L CONSTRUCTORS CANADA INC |
Issued Date: | November 13, 2002 |
File Close Date: | July 03, 2003 |
Associated Properties
Address | Zone | More |
---|---|---|
6631 ISLAND HIGHWAY N | CC4 | Property Report |
Process Steps
Task | Status |
---|---|
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PASSED |
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PASSED |
FIRELINE
Fireline for the sprinkler system must be complete and visable for inspection. |
PARTIAL |
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PASSED |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PASSED |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
FAILED |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PASSED |
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
OCCUPANCY-OLD | FAILED |
FINAL-OLD
Final approval as per requirements on plans. |
PARTIAL |
FINAL-OLD
Final approval as per requirements on plans. |
PASSED
2003-07-03 |
Map |
---|
![]() |
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.