BP104879 - 5444 Dunster (parent 5434 Dunster)

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP104879 - 5444 Dunster (parent 5434 Dunster)
Neighbourhood: Pleasant Valley    
Street Address: 5444 Dunster (parent 5434 Dunster)
Type of Application: Garage / Carport Permit
File Number: BP104879
Date Application Submitted: June 26, 2002
Application Description: 40' x 30' garage and 32' x 40' workshop, with DVP for height and size
Application Status: COMPLETED
Permit Value: $44,000.00
Building Area: 230.40 M2
2,480.00 ft2
Issued Date: July 23, 2002
File Close Date: February 07, 2007

Process Steps

Task Status
LATERAL BRACING & SHEATHING

All nailing and blocking associated with braced wall panels to be completed for this inspection. Wood-based interior braced wall panels to be sheathed. Exterior braced wall panel locations to be clearly marked out on the interior and exterior. Interior braced wall panels to be clearly marked so their location can be seen now and later at the time of INTERIOR BRACED WALL PANEL INSPECTION. Additional anchor bolts shall be installed two per braced wall panel where a building contains framed walls supporting more than two floors.

COMPLETED
FOOTING/FORMS

Inspection of forms prior to any cement being poured . For footing inspection, forms must be complete and approved plans (complete with City Stamp) must be onsite.

PARTIAL
FOOTING/FORMS

Inspection of forms prior to any cement being poured . For footing inspection, forms must be complete and approved plans (complete with City Stamp) must be onsite.

PASSED
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PARTIAL
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PASSED
UNDERSLAB PLUMBING

Complete underslab plumbing must be visible.

FAILED
UNDERSLAB PLUMBING

Complete underslab plumbing must be visible.

CANCELLED
UNDERSLAB PLUMBING

Complete underslab plumbing must be visible.

CANCELLED
FRAMING

Rough-in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PASSED
FINAL-OLD

Final Approval as per requested on plans.

FAILED
FINAL-OLD

Final Approval as per requested on plans.

PASSED

2007-02-07

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.