BP104818 - 1613 BOWEN
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP104818 - 1613 BOWEN | |
|---|---|
| Neighbourhood: | Northfield |
| Street Address: | 1613 BOWEN |
| Type of Application: | Commercial / Multi-Res Alteration |
| File Number: | BP104818 |
| Date Application Submitted: | June 14, 2002 |
| Application Description: |
Expansion of the exisiting Harbour City Motorsport with adjoining suite. Total area will be used by Harbour City Motorsport. Scope of work includes installation of beams, posts, footings. Existing mezzanine complies with 3.2.8. Installation of new wall around floor opening with 45min FS and openings shall have wired glass that shall not exceed 11m2 and have no dimension greater than 3.7m. New exterior exit from the 2nd storey and to comply with 9.8. for construction of stairs, guards, handrails. Meets Travel distance 30m. Existing building footprint= 535.56m2. Adding 39m2 second floor 45min FS betweeen floors. Part 9 building, 2 storeys, Occupancies Group D, E, F2. not sprinklered , no fire alarm. combustible construction, 45 min FS and loadbearing supports. Other FS F2 to E, 2 hours 8" concrete block exisiting. Existng 1 hour FS existed between suite and is being partially removed for the expansion. Existing South and West wall 2hr FRR = 8" wall complies. |
| Application Status: | COMPLETED |
| Permit Value: | $125,000.00 |
| Issued Date: | June 14, 2002 |
| File Close Date: | October 23, 2002 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 1613 BOWEN ROAD | COR3 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
FOOTING/FORMS
Inspection of forms prior to any concrete being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PASSED |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
CANCELLED |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PASSED |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
|
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PASSED |
|
FINAL-OLD
Final approval as per requirements on plans. |
PARTIAL |
|
FINAL-OLD
Final approval as per requirements on plans. |
FAILED |
|
FINAL-OLD
Final approval as per requirements on plans. |
PASSED
2002-10-23 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)