BP104676 - 5537 Big Bear Ridge

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP104676 - 5537 Big Bear Ridge
Neighbourhood: Pleasant Valley    
Street Address: 5537 Big Bear Ridge
Type of Application: Locate Permit
File Number: BP104676
Date Application Submitted: May 07, 2002
Application Description: locate 11.5' x 57.33' mobile home as addition to existing home and construct a 12'x22' detached garage

January 15th, 2004 - Memo sent to Ralph requesting that Council be approached to have a notice placed on the land title.
TW
Application Status: RETIRED
Permit Value: $3,000.00
Building Area: 61.20 M2
658.75 ft2
Issued Date: June 21, 2002
File Close Date: January 15, 2004

Associated Properties

Address Zone More
5537 BIG BEAR RIDGE R5 Property Report

Process Steps

Task Status
PRELIMINARY PLANNING APPROVAL

Approval from Planning

APPROVED
FOOTING/FORMS

Inspection of Forms prior to any cement being poured. For Footing inspection, forms must be complete and approved plans (complete with City Stamp) must be onsite.

PASSED
FOOTING/FORMS

Inspection of Forms prior to any cement being poured. For Footing inspection, forms must be complete and approved plans (complete with City Stamp) must be onsite.

PASSED
PERIMETER DRAIN

For Perimeter Drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

FAILED
FRAMING

When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco.

PASSED
LATERAL BRACING & SHEATHING

All nailing and blocking associated with braced wall panels to be completed for this inspection. Wood-based interior braced wall panels to be sheathed. Exterior braced wall panel locations to be clearly marked out on the interior and exterior. Interior braced wall panels to be clearly marked so their location can be seen now and later at the time of INTERIOR BRACED WALL PANEL INSPECTION. Additional anchor bolts shall be installed two per braced wall panel where a building contains framed walls supporting more than two floors.

FAILED
LATERAL BRACING & SHEATHING

All nailing and blocking associated with braced wall panels to be completed for this inspection. Wood-based interior braced wall panels to be sheathed. Exterior braced wall panel locations to be clearly marked out on the interior and exterior. Interior braced wall panels to be clearly marked so their location can be seen now and later at the time of INTERIOR BRACED WALL PANEL INSPECTION. Additional anchor bolts shall be installed two per braced wall panel where a building contains framed walls supporting more than two floors.

PASSED
Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.