BP104494 - 6324 Metral - SCANNED

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP104494 - 6324 Metral - SCANNED
Neighbourhood: Pleasant Valley    
Street Address: 6324 Metral - SCANNED
Type of Application: Commercial / Multi / Industrial
File Number: BP104494
Date Application Submitted: March 13, 2002
Application Description: revised october 15, 2002, no fire alarm installed not required by code. two exit provided for video store and two exits provide for music store. single exit meets TD 25m for upper floor Group D.

Part 9 building, Sprinklered, fire alarm both not required by code.
3 CRU's, Front unit, Arbutus music, Group E, 145.8m2 single exit meets 25m Crawl space= 116 m2 interconnection with Arbutus meets 3.2.8. Rear unit Group E, 156 m2 single exit meets 25m. Upper unit Group D, 121.7 single exit meets 25m. Total area = 423.5m2 does not include crawl space. 45 min FRR/FS for floor and loadbearing supports including the floor over the crawlspace considered a basement for floor rating.. 45 min FRR/FS between suites and FS(fire separation) of the lobby. Handicapped washroom shared and located in lobby. 2 hour FRR required for the exposed building face on the left property line. Separate permits for tenant improvements.
Application Status: COMPLETED
Permit Value: $320,000.00
Builder: R W (BOB) WALL CONTRACTING LTD
Issued Date: June 21, 2002
File Close Date: October 25, 2002

Associated Properties

Address Zone More
6324 METRAL DRIVE CC4 Property Report

Process Steps

Task Status
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PASSED
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

FAILED
UNDERSLAB INSULATION

Inspection required prior to placing slab concrete.

PASSED
STORM CONNECTION

Pipe and connection must be visible for inspection.

PASSED
SANITARY CONNECTION

Pipe and connection must be visible for inspection.

PASSED
WATER CONNECTION

Pipe and connection must be visible for inspection.

PASSED
WATER CONNECTION

Pipe and connection must be visible for inspection.

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

CANCELLED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PASSED
PAPER/FLASHING/WATERPROOFING

When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco.

PASSED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

FAILED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

CANCELLED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PASSED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PASSED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

FAILED
FINAL-OLD

Final approval as per requirements on plans.

PARTIAL
FINAL-OLD

Final approval as per requirements on plans.

FAILED
FINAL-OLD

Final approval as per requirements on plans.

FAILED
FINAL-OLD

Final approval as per requirements on plans.

PARTIAL
FINAL-OLD

Final approval as per requirements on plans.

PASSED

2002-10-25

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.