BP104381 - 6085 Uplands -- Drawings Scanned/Attached

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP104381 - 6085 Uplands -- Drawings Scanned/Attached
Neighbourhood: Dover    
Street Address: 6085 Uplands -- Drawings Scanned/Attached
Type of Application: Commercial / Multi / Industrial
File Number: BP104381
Date Application Submitted: February 11, 2002
Application Description: Phase 3 - Building No. 6 - Block "F" -
30 beds, Group B2, Care facility, 2 Storeys, combustible construction, sprinklered, 2 stage fire alarm system. smoke detectors in sleeping rooms, corridor- means of egress, exit shafts. Building Classification 3.2.2.40 , 45 min FRR/FS for floor assemblies. Fire separations for Walls separating corridors serving sleeping rooms from adjacent rooms and walls between sleeping rooms. Self closers not required between patient sleeping rooms . 45min FRR exposing building face.
6th building divided by 2hr. firewall. 1.5hr, Fire doors/closure in firewalls Firewall built under building permit Bp102833. Building area = 545.6m2 per floor. Total gross floor area =1091.2m2.
Application Status: COMPLETED
Permit Value: $600,000.00
Builder: KASPER INVESTMENTS-RETIREMENT CONCEPTS
Issued Date: March 14, 2002
File Close Date: July 12, 2002

Process Steps

Task Status
FOOTING/FORMS

Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PASSED
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

FAILED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

FAILED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PASSED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

FAILED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PASSED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

FAILED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PASSED
PLUMBING FINAL-OLD

All fixtures must be in place.

FAILED
OCCUPANCY-OLD PARTIAL
OCCUPANCY-OLD PARTIAL
OCCUPANCY-OLD PARTIAL
OCCUPANCY-OLD PASSED

2002-07-12

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.