BP104369 - 7 - 2480 Kenworth
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP104369 - 7 - 2480 Kenworth | |
|---|---|
| Neighbourhood: | Diver Lake |
| Street Address: | 7 - 2480 Kenworth |
| Type of Application: | Leasehold Improvements |
| File Number: | BP104369 |
| Date Application Submitted: | February 06, 2002 |
| Application Description: |
Indoor skate park. 445.9 m2 A2 (assembly) occupancy in 2230 m2 unsprinklered building of mixed E/F2/D occupancies. Building has a history of assembly uses, this is not a change of occupancy for the overall building. 2-hour fire resistance rating required at wall between this and adjacent suites. Occupant load is 100 persons, a permanent sign must be posted. Ratio male to female is 80/20, one female wc and 2 male wc provided. One existing washroom altered to provide h/c access. Rear exit stair altered to meet BCBC 1998 requrements for rise, run, handrail, guard etc. Two exits required, turning exit doors to swing in exit travel direction. Exit signage and emergency lighting to be upgraded to meet BCBC 1998. |
| Application Status: | COMPLETED |
| Permit Value: | $2,500.00 |
| Builder: | FLIPSIDE SKATE COMPANY LTD |
| Issued Date: | March 21, 2002 |
| File Close Date: | April 29, 2002 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 2480 KENWORTH ROAD | I2 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
FAILED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
|
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PASSED |
|
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
CANCELLED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
CANCELLED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
CANCELLED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
FAILED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
|
FINAL-OLD
Final Approval as per requirements on plans. |
FAILED |
|
FINAL-OLD
Final Approval as per requirements on plans. |
PARTIAL |
|
FINAL-OLD
Final Approval as per requirements on plans. |
PASSED
2002-04-29 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.