BP104368 - 650 Terminal - Drawings Scanned/Attached
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP104368 - 650 Terminal - Drawings Scanned/Attached | |
|---|---|
| Neighbourhood: | Downtown/Old City |
| Street Address: | 650 Terminal - Drawings Scanned/Attached |
| Type of Application: | Commercial / Multi-Res Alteration |
| File Number: | BP104368 |
| Date Application Submitted: | February 05, 2002 |
| Application Description: |
received January 13, 2003 revised drawings. received May 27,2003 facelift to existing sign tower structure. Renovation to existing mall to include a New Food court, New Shell CRU's and shell CRU' for the Food tenants and a Conference centre room. New Female and Male washrooms and Accessible Toilet Room. Accessible principle entrances. New west entrance includes an encroachment agreement with the City. Future permits required for Tenant Improvements. Building Area: 21696 m2. Increased Occupant load by 420 persons. Building Classification 3.2.2.57, Non combustible construction , Sprinklered , Fire alarm, 2hr FRR/FS for the roof top parking. Exits 2hr FRR/FS. Unobstructed 5m corridors. Fire protection Report for the use of combustible component , March 16, 1989 Report. |
| Application Status: | COMPLETED |
| Permit Value: | $1,200,000.00 |
| Builder: | TECHNIFIELD CONTRACTING LTD |
| Issued Date: | November 26, 2002 |
| File Close Date: | December 02, 2004 |
Process Steps
| Task | Status |
|---|---|
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PASSED |
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
FAILED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PARTIAL |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PARTIAL |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PARTIAL |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
|
FINAL-OLD
Final approval as per requirements on plans. |
CANCELLED |
|
FINAL-OLD
Final approval as per requirements on plans. |
PASSED
2004-12-02 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)