BP103897 - 2010 Boxwood Road
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP103897 - 2010 Boxwood Road | |
|---|---|
| Neighbourhood: | Northfield |
| Street Address: | 2010 Boxwood Road |
| Type of Application: | Commercial / Multi / Industrial |
| File Number: | BP103897 |
| Date Application Submitted: | August 14, 2001 |
| Application Description: | BP103903 for foundation and on-site servicing. Building area 1183.55m2 . Mezzanine (front suite) 21.45m2. Building Classification 3.2.2.71, Group F Division 2, one storey with mezzanine in front suite. Pre-engineered building. Sprinklered for bylaw only. No floor or roof rating required. Usable mezzanine is 10'-6" x 22' . Remainder of mezzanine is inaccessible (does not meet travel distance and the floor is not designed to support a floor load). Signage regarding limited use of mezzanine must be permanently attached to the guard. Exposing building face on the right side is required to be 2 hr FRR noncombustible, on left side requires 1 hour FRR. Equivalency report by A. Harmsworth provided for sprinklers as equivalent to the required fire resistance ratings. Maximum travel distance to exits: 30m. Handicap washroom in front suite and rough in washrooms in the remainder of the building. Front suite to be completed. Separate permits required to finish other suites. |
| Application Status: | COMPLETED |
| Permit Value: | $288,000.00 |
| Builder: | WINDLEY CONTRACTING LTD |
| Issued Date: | October 03, 2001 |
| File Close Date: | December 11, 2001 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 2010 BOXWOOD ROAD | I3 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PASSED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
|
PAPER/FLASHING/WATERPROOFING
When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco. |
PARTIAL |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
CANCELLED |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
CANCELLED |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PASSED |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PASSED |
|
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PASSED |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
FAILED |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
FAILED |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PASSED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
FAILED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
| OCCUPANCY-OLD | PARTIAL |
| OCCUPANCY-OLD |
PASSED
2003-07-03 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)