BP103635 - 1995 Boxwood
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP103635 - 1995 Boxwood | |
|---|---|
| Neighbourhood: | Northfield |
| Street Address: | 1995 Boxwood |
| Type of Application: | Commercial / Multi / Industrial |
| File Number: | BP103635 |
| Date Application Submitted: | May 18, 2001 |
| Application Description: |
Part 3 Building, Group F2, 3.2.2.72., sprinklered, fire alarm required for spatial considerations. Total floor area = 1475.8. Building Area 1404.4 m2. Building is divided into two units. One unit for a future warehouse space is 372.8m2 with two required exits, rough-in plumbing is provided only and will require a future permit to complete. The second unit is for a workshop and office; three required exits. The workshop is 931.0 m2 and has a mezzanine of 71.5m2. (7.5% of the floor area) Office area = 100.9 m2. The mezzanine is not considered a storey and is not required to be rated. Accessible washroom is provided in the office. Letter from owner in file for Occupant load of 15 for washroom considerations. Occupant load for life safety = 60. Spatial considerations. S.E. 1 hr. FRR.(F2 fire compartment) N.W. 2 hr FRR (F2 fire compartment) N.W.1hr FRR( D fire compartment) . 45 min FRR/FS between units and fire compartment. |
| Application Status: | COMPLETED |
| Permit Value: | $425,000.00 |
| Builder: | HEROLD ENGINEERING LTD |
| Issued Date: | June 20, 2001 |
| File Close Date: | November 29, 2002 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 1995 BOXWOOD ROAD | I3 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PASSED |
|
FIRELINE
Fireline for the sprinkler system must be complete and visable for inspection. |
FAILED |
|
FIRELINE
Fireline for the sprinkler system must be complete and visable for inspection. |
PASSED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PARTIAL |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PASSED |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
FAILED |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PASSED |
|
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
CANCELLED |
|
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PASSED |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
FAILED |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
FAILED |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
CANCELLED |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
CANCELLED |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PARTIAL |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PASSED |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PASSED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
| OCCUPANCY-OLD | FAILED |
| OCCUPANCY-OLD | FAILED |
|
FINAL-OLD
Final approval as per requirements on plans. |
PASSED
2002-11-29 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)