BP103184 - 2020 Boxwood -- Scanned
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP103184 - 2020 Boxwood -- Scanned | |
|---|---|
| Neighbourhood: | Northfield |
| Street Address: | 2020 Boxwood -- Scanned |
| Type of Application: | Commercial / Multi / Industrial |
| File Number: | BP103184 |
| Date Application Submitted: | November 23, 2000 |
| Application Description: |
New premanufactured steel bldg (F3 w/office) Total Delivery Systems 695.25 m2 building area Combustible content limit of not more than 50kg/m2 Group F Division 3 3.2.2.79. Accessible one storey, sprinklered building with fire alarm. The mezzanine does not require fire resistance rating at floor. The Mezzanine is 7.4% of the floor area and can be enclosed without special requirements. No rating or separation is required between the mezzanine and the warehouse. Accessible washroom to comply with 3.7.4.8.9) |
| Application Status: | COMPLETED |
| Permit Value: | $184,000.00 |
| Issued Date: | January 05, 2001 |
| File Close Date: | March 06, 2001 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 2020 BOXWOOD ROAD | I3 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
FIRELINE
Fireline for the sprinkler system must be complete and visable for inspection. |
CANCELLED |
|
FIRELINE
Fireline for the sprinkler system must be complete and visable for inspection. |
PARTIAL |
|
FIRELINE
Fireline for the sprinkler system must be complete and visable for inspection. |
PARTIAL |
|
FIRELINE
Fireline for the sprinkler system must be complete and visable for inspection. |
PASSED |
|
STORM CONNECTION
Pipe and connection must be visible for inspection. |
PASSED |
|
SANITARY CONNECTION
Pipe and connection must be visible for inspection. |
PASSED |
|
WATER CONNECTION
Pipe and connection must be visible for inspection. |
CANCELLED |
|
WATER CONNECTION
Pipe and connection must be visible for inspection. |
PARTIAL |
|
WATER CONNECTION
Pipe and connection must be visible for inspection. |
PARTIAL |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PASSED |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PASSED |
|
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PASSED |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
FAILED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
FAILED |
| OCCUPANCY-OLD | FAILED |
| OCCUPANCY-OLD | CANCELLED |
| OCCUPANCY-OLD |
PASSED
2001-03-06 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)