BP103033 - 5070 Uplands -- Drawings Scanned/Attached

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP103033 - 5070 Uplands -- Drawings Scanned/Attached
Neighbourhood: Rutherford    
Street Address: 5070 Uplands -- Drawings Scanned/Attached
Type of Application: Commercial / Multi / Industrial
File Number: BP103033
Date Application Submitted: September 27, 2000
Application Description: Separate permit for the mechanical/plumbing/sprinklers and electrical. Future permits for Tenants are required.
Shell permit only X reference bp 103055 for the foundation permit. Two storey office/retail building, Part 3 building. Combustible construction, Sprinklered, Fire alarm system. 618m2 total first storey, includes 226m2 Office and 392m2 retail, 1128 total 2nd storey, includes 838m2 Office (Group D)and 290m2 Retail (Group E). Building Classification: 3.2.2.62, 45min. Fire Separation(FS)/Fire Resistance rating (FRR) for the floor and all loadbearing supports. Demising walls between retail (E) and office (D) is required to be 45min FRR/FS.Unenclosed exit stairs/ramp within 3m of an unprotected opening is required to be protected with wired glass or a 45min rated door and closer in conformance with 3.2.3.12.4). All suites are required to be accessible for persons with disabilities. Sprinklered by BCBC, fire alarm is required.
Application Status: COMPLETED
Permit Value: $1,000,000.00
Builder: CANADIAN IMPERIAL BANK OF COMMERCE
Issued Date: January 11, 2001
File Close Date: June 19, 2001

Process Steps

Task Status
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PASSED
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

FAILED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

FAILED
OCCUPANCY-OLD FAILED
OCCUPANCY-OLD PASSED

2001-06-19

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.