BP103033 - 5070 Uplands -- Drawings Scanned/Attached
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP103033 - 5070 Uplands -- Drawings Scanned/Attached | |
|---|---|
| Neighbourhood: | Rutherford |
| Street Address: | 5070 Uplands -- Drawings Scanned/Attached |
| Type of Application: | Commercial / Multi / Industrial |
| File Number: | BP103033 |
| Date Application Submitted: | September 27, 2000 |
| Application Description: |
Separate permit for the mechanical/plumbing/sprinklers and electrical. Future permits for Tenants are required. Shell permit only X reference bp 103055 for the foundation permit. Two storey office/retail building, Part 3 building. Combustible construction, Sprinklered, Fire alarm system. 618m2 total first storey, includes 226m2 Office and 392m2 retail, 1128 total 2nd storey, includes 838m2 Office (Group D)and 290m2 Retail (Group E). Building Classification: 3.2.2.62, 45min. Fire Separation(FS)/Fire Resistance rating (FRR) for the floor and all loadbearing supports. Demising walls between retail (E) and office (D) is required to be 45min FRR/FS.Unenclosed exit stairs/ramp within 3m of an unprotected opening is required to be protected with wired glass or a 45min rated door and closer in conformance with 3.2.3.12.4). All suites are required to be accessible for persons with disabilities. Sprinklered by BCBC, fire alarm is required. |
| Application Status: | COMPLETED |
| Permit Value: | $1,000,000.00 |
| Builder: | CANADIAN IMPERIAL BANK OF COMMERCE |
| Issued Date: | January 11, 2001 |
| File Close Date: | June 19, 2001 |
Process Steps
| Task | Status |
|---|---|
|
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PASSED |
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
FAILED |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PARTIAL |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
|
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
FAILED |
| OCCUPANCY-OLD | FAILED |
| OCCUPANCY-OLD |
PASSED
2001-06-19 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)