BP102593 - 3023 Barons Rd
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP102593 - 3023 Barons Rd | |
|---|---|
| Neighbourhood: | Rutherford |
| Street Address: | 3023 Barons Rd |
| Type of Application: | Commercial / Multi-Res Alteration |
| File Number: | BP102593 |
| Date Application Submitted: | April 11, 2000 |
| Application Description: |
New address 3023 Barons Road. Consolidation of two existing buildings into one building. Adding 49m2 to existing building. Interior renovation. Building classification (Part 3) : 3.2.2.25. Group A2 . 509m2. One storey, one street, combustible construction with the roof assembly having a Fire resistance rating of not less than 45min. Fire resistance Rating.( 5/8" Type X Gypsum Board.) Loadbearing supports to be noncombustible or have 45min Fire-resistance rating. Plumbing is required to be non-combustible. Ceiling membrane openings (fire flaps) to be protected in accordance with 3.1.9.5. if penetrating the 45 min. roof assembly. 3 exits provided . Occupant load 150. One Unisex - Accessible washroom provided. Total washrooms 2 male 4 female. Door release hardware on exit doors from restaurant floor areas. |
| Application Status: | COMPLETED |
| Permit Value: | $115,000.00 |
| Building Area: |
518.00 M2 5,575.70 ft2 |
| Issued Date: | July 04, 2000 |
| File Close Date: | February 21, 2001 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 3023 BARONS ROAD | COR3 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
FOOTING/FORMS
Inspection of forms prior to any concrete being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PASSED |
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PASSED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PASSED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
|
FINAL-OLD
Final approval as per requirements on plans. |
FAILED |
|
FINAL-OLD
Final approval as per requirements on plans. |
PARTIAL |
|
FINAL-OLD
Final approval as per requirements on plans. |
PASSED
2001-02-21 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)