BP102580 - 6201 Blueback
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP102580 - 6201 Blueback | |
|---|---|
| Neighbourhood: | Dover |
| Street Address: | 6201 Blueback |
| Type of Application: | Leasehold Improvements |
| File Number: | BP102580 |
| Date Application Submitted: | April 07, 2000 |
| Application Description: | 7-11 - Conversion of existing "Terry Save-Rite " to 7-11 and one CRU unit. Part 9, 2 storey, Unsprinklered, Combustible building. Main floor area (Group E)(existing 594m2). Upper floor area(Group D) existing 200m2). Existing 45 min. FRR/FS between floors, 0 rating roof. Main Floor is separated from the New CRU (196m2) by a new 45min demising wall, The new 7-11 will have an Accessible Washroom. The New CRU is required to have two exits. The exit at the rear of the new CRU passes by a door in the storage area which is required to have a 45min door & closer and the overhead door is to be removed and filled in with a new exterior wall. The Upper floor is approved for office use (Group D) only, except existing mech. room. Upper floor is part of the 7-11 store. New 45min door & closer is required at the top of the stairs to meet the 25m travel distance. 45 min FRR/FS for exit from 2nd floor. Non-combustible plumbing. |
| Application Status: | COMPLETED |
| Permit Value: | $55,000.00 |
| Building Area: |
804.00 M2 8,654.18 ft2 |
| Builder: | L J PROJECTS LTD |
| Issued Date: | May 02, 2000 |
| File Close Date: | June 20, 2000 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 6201 BLUEBACK ROAD | CC1 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible. |
PASSED |
|
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible. |
PASSED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
|
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PARTIAL |
|
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PARTIAL |
|
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PASSED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
|
FINAL-OLD
Final Approval as per requirements on plans. |
PARTIAL |
|
FINAL-OLD
Final Approval as per requirements on plans. |
PASSED
2000-06-20 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)