BP102150 - 2517 Bowen

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP102150 - 2517 Bowen
Neighbourhood: Diver Lake    
Street Address: 2517 Bowen
Type of Application: Commercial / Multi-Res Alteration
File Number: BP102150
Date Application Submitted: October 29, 1999
Application Description: ADD 3288 sq ft GARDEN CENTRE to south side of existing, sprinklered, non-combustible, 41471 sq ft CO-OP. (3004 sq ft existing garden centre demolished under BP102091.)
Add 10 x 35 ft FRONT ENTRANCE VESTIBULE and extend CANOPY along front of building.
ADD 580 sq ft MEZZANINE adjacent front entrance. Demolish 340 sq ft mezzanine adjacent front entrance.
REMOVE demising wall to old Credit Union space for new administration offices. 3.2.2.60 (group E sprinklered) 1998 BC Building Code applies: combustible construction OK, max 7200 sq m. (Total will be 4191 sq m.), max one storey, 3/4 hour FRR floors, mezz, supports. 0 hour FRR roof.
Application Status: COMPLETED
Permit Value: $405,000.00
Builder: MCINTOSH G A CONSTRUCTION LTD
Issued Date: January 05, 2000
File Close Date: October 18, 2000

Process Steps

Task Status
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PASSED
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PASSED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

FAILED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PASSED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

FAILED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PASSED
PLUMBING FINAL-OLD

All fixtures must be in place.

PARTIAL
PLUMBING FINAL-OLD

All fixtures must be in place.

PASSED
FINAL-OLD

Final approval as per requirements on plans.

PARTIAL
FINAL-OLD

Final approval as per requirements on plans.

PASSED

2000-10-18

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.